Buildings with Response Control Systems in Japan
Today, there are more than 30 buildings with response control systems. The system is defined as one that suppresses or controls the response to the vibrational motion input of the buildings,...

Study of Failures of Towers and Tall Buildings Under Wind Loading
In this paper, two kinds of wind-excited limit states on a tall structure are investigated and corresponding formulae for the limit wind pressures are presented. In solving the wind-excited...

Response of Isolated Structures to Recent California Earthquakes
A significant amount of research and development, shake table testing computer modelling and real world applications have been performed with the seismic isolation design concept in the...

Response of Base Isolated Buildings in Japan to Recent Earthquakes
On February 2nd in 1992, more than 20 base isolated buildings in Tokyo experienced an earthquake of JMA seismic intensity 5. In this event, many acceleration records of isolated buildings...

Evaluation of Code Accidental-Torsion Provisions Using Earthquake Records from Buildings
Building code provisions for accidental torsion are evaluated from analysis of earthquake-induced motions of three nominally-symmetric-plan buildings. The results demonstrate that the...

Building Separation Rules to Avoid Seismic Pounding
A method to estimate the required separation to preclude pounding between adjacent buildings is presented. It accounts for the effect of yielding on the vibration phase of adjacent buildings....

Displacement Amplification Factor for Seismic Design Provisions
To estimate the maximum roof and story drifts occurring during severe earthquakes, the UBC and NEHRP use 3Rw/8 and Cd...

Evaluation of US Seismic Code Provisions for Asymmetric-Plan Systems
The effects of plan asymmetry on the earthquake response of code-designed, one-story systems are identified with the objective of evaluating how well these effects are represented by torsional...

Data Base for Seismis Rick Assessment in Mexico City
We describe a model to estimate expected ground motions and expected damage, based on intensity damage relations derived for 14 classes of buildings representative of Mexico City construction....

Earthquake Resistant Design and Construction of Reinforced Concrete Buildings. The Practice in Mexico After 1985
The evolution of the design and construction practice of reinforced concrete buildings in Mexico is presented in terms of materials, structural systems, member design and reinforcement...

Techniques for Seismic Rehabilitation of Buildings in Mexico City
The 1985 earthquake in Mexico City caused collapse or damage of a large number of engineered buildings. After this event several hundreds of buildings were retrofitted using several techniques....

Seismic Upgrade Design of Buildings
Building owners and users in seismically prone areas are becoming increasingly aware of the potential risks associated with the seismically hazardous buildings in the region specially...

Effect of First-Story Shearwalls on Earthquake-Resistant Buildings
A Practical system for earthquake-resistant building design is described. The system utilizes Teflon sliders at the top of the first story framed shearwalls to carry a portion of the superstructure....

Damage Assessment for Reinforced Concrete Buildings with Shear Walls
This paper tries to establish the analytical method of damage assessment for R.C. buildings with shear walls before or after earthquake. Incremental nonlinear spectrum analysis, using...

Code Provisions for Unreinforced Masonry Bearing Wall Buildings in California
Prior to the Long Beach earthquake of 1933, unreinforced masonry (URM) construction was usual in California, as it still is in many areas of the United States. The poor performance of...

Earthquake Strengthening of a Twelve Story Non-Ductile Concrete Frame Building with Unreinforced Masonry Using Displacement Control Criterion
The structural concern with the Cooper Arms Apartment building when subjected to ground shaking was the in-plane and out-of-plane forces on the infill and consequences of the infill resisting...

Fundamental Issues in Seismic Safety in Midwestern U.S. Due to Hazard/Vulnerability Relation
Problems in establishing and mitigating seismic risk in urban areas when seismicity is not confidently based on instrumental records are discussed. Urban Southwestern Ohio is a specific...

Seismic Standards for Existing Federally Owned and Leased Buildings
Public Law 101-614 requires the Interagency Committee on Seismic Safety in construction to develop 'standards for assessing and enhancing the seismic safety of existing buildings constructed...

Design Wind Speed and Design Criteria of Buildings
Design load recommendations of Architectural Institute of Japan(A.I.J.) are revised according to a common principle to all kinds of loads. The basic wind speed is defined as the annual...

Prediction of Wind-Induced Responses and Wind Loads
The Recommendations for Wind Loads of Buildings and Structures of the Architectural Institute of Japan have now been updated. This paper presents the drafts of the new Recommendations...

 

 

 

 

Return to search