Experimental Study of the Transient Temperature Distributions in Concrete
A small scale, preliminary experimental effort to quantify the randomness of the thermal diffusivity of concrete has been undertaken. Two sets of cylinders have been instrumented with...

Nonlinear Diffraction of Random Waves by a Vertical Cylinder
In this study, nonlinear diffraction of random waves by a vertical uniform circular cylinder in deep water is analyzed. The incident wave field is represented by a stationary random process,...

Nonlinear Wave Runup on Large Circular Cylinders
Various design methods for computing nonlinear wave runup on a large-diameter circular cylinder are presented. First, empirical correlations are developed between the observed maximum...

Second-Order Hydrodynamic Interactions Between a Pair of Vertical Cylinders in Irregular Waves
A complete second-order solution is given for the hydrodynamic forces on a pair of bottom-mounted, surface-piercing, vertical circular cylinders in bichromatic seas. The constant structural...

Wave Slamming on a Horizontal Circular Cylinder
The present paper describes an experimental study of the wave slamming force on a horizontal circular cylinder located near the free surface. The vertical force on a cylinder and the corresponding...

Structural Responses in Mechatronics
The design analysis of a circular cylinder, ring-stiffened intermittently, subject to conducting flow, is presented herein (Fan, 1986 & 1990). This composite cylinder is made of...

Prestressed Concrete Pipe Field Test
Strain changes in the prestressing wires and deflections of a 2130-mm-diameter precast (embedded cylinder), prestressed concrete pipe were measured during earth backfilling operations....

Investigation & Rehabilitation of Seattle's Tolt Pipeline
Seattle Water Department's Tolt Pipeline brings water 24 miles from storage in the Cascade Mountains into city and suburban distribution systems. Twenty-three miles of this...

In-Situ Evaluation of 30-In. (762-mm) Diameter Prestressed Concrete Lined-Cylinder Pipeline
The results of an extensive investigation to evaluate the in-service condition and future serviceability of an existing lake water make-up pipeline are briefly described herein. The pipeline...

Combined Load Testing of Prestressed Concrete Cylinder Pipe
A series of combined load tests were run on prestressed concrete cylinder pipe in order to evaluate a proposed new method of design for pipe made to AWWA Standard C301. These tests involved...

Innovative Concept for Prestressed Pressure Pipe
A new design and manufacturing concept was developed by General Atomics for prestressed pressure pipe. With this new concept, patented in the U.S. and in the major industrialized nations,...

Failure of Prestressed Concrete Embedded Cylinder Pipe
In 1964, the Ontario Provincial Government undertook to supply water to the City of London (current population 300,000). The supply source was from Lake Huron near Grand Bend, Ontario...

Evaluation of Combined Load Tests of Prestressed Concrete Cylinder Pipe
Combined load tests of prestressed concrete cylinder pipe, presented by Tremblay in the proceedings of this conference, are analyzed. Data gathered during the tests includes first visible...

Analysis of Alternative Pipe Materials for a Major Public Water Agency
A major southwestern public water agency has historically specified the exclusive use of prestressed concrete cylinder pipe (PCCP) for large diameter water transmission mains. Due to the...

Twin Pipeline Crossing of the Fraser River
A new creek water supply was developed for the communities of Mission and Matsqui, British Columbia, Canada, in the early eighties. Over 60 kilometres of 450 mm to 900 mm diameter ductile...

Forces Acting on a Vortex-Excited Vibrating Cylinder in Planar Oscillatory Flow
An experimental investigation into the vortex-excited vibration of a circular cylinder in planar oscillatory flow has been made with emphasis being placed on the amplification of the forces...

Long-Term Strength Gain or High Strength Concrete as Monitored by Drilled Cores
An evaluation was made of the relationship between standard cylinders, four-inch by eight-inch cylinders, and drilled cores. The evaluation results showed that the strengths obtained from...

Compressive Strength Relationship Between Cylinder Tests and Core Tests
A core obtained from any field cured structural member will be inherently different than the field cured cylinder used as a control. Consequently, comparisons with field cured cylinders...

Stability of Cylindrical Shells With and Without Cutouts and Subjected to Wind Load
The cylindrical storage tanks with and without cutouts are analyzed using nonlinear finite element analysis. All the cylinders are fixed at the base. Two types of cylindrical tanks without...

Circular Tubes and Shells 4th Edition of SSRC Guide