In-Situ Evaluation of 30-In. (762-mm) Diameter Prestressed Concrete Lined-Cylinder Pipeline

by D. M. Schultz, Construction Technology Lab Inc, United States,
R. G. Oesterle, Construction Technology Lab Inc, United States,
J. J. Roller, Construction Technology Lab Inc, United States,



Document Type: Proceeding Paper

Part of: Pipeline Design and Installation

Abstract:

The results of an extensive investigation to evaluate the in-service condition and future serviceability of an existing lake water make-up pipeline are briefly described herein. The pipeline consisted of 30-in. (762-mm) diameter prestressed concrete lined cylinder pipe with a length of approximately 5 miles (8047-m). During the 6-year period since installation, the pipeline had experienced five separate ruptures. As a result of the ruptures, an in-depth investigation was performed by the authors.



Subject Headings: Concrete cylinder pipes | Concrete pipes | Reinforced concrete | Prestressed concrete | Steel pipes | Prestressing | Pipe sizes

Services: Buy this book/Buy this article

 