Regional Wastewater Reuse in the Nueces Estuary
The results of this study indicate that the firm yield lost to the release requirements of the Texas Water Commission Interim Release Order can be recovered by diverting treated wastewater...
Surface Water Quality Modeling in the Rio Grande
The City of Albuquerque (City) in New Mexico owns and operates the Southside Water Reclamation Plant (SWRP), which discharges an average of 200623 m3/d...
Setting Competitive Water Reuse Rates
Palm Beach County Water Utilities Department (WUD) is preparing to provide reclaimed water service to several large irrigators near the County's Southern Region Wastewater Treatment Plant...
Wastewater Reclamation at Davenport, Washington
The City of Davenport, Washington went through an extended process to update their undersized wastewater treatment and irrigation reclamation systems for municipal wastewater. The process...
Reducing Discharges from San Francisco to the Bay
The City and County of San Francisco (City) is fairly unique in the west because it has a combined sanitary and storm water system. When the current Wastewater Master Plan (WWMP) was completed...
A New Angle on Ground-Water Remediation
When engineers from Black & Veatch Waste Science (BVWS) went to Tinker Air Force Base to examine the site of a hazardous waste cleanup job the service had hired them for, they...
Computerized Facility Information Management Systems
The paper describes a computerized information system that can be used in place of the traditional operations and maintenance manual used by facilities personnel. Plant operations and...
SCADA System Controls Combined Sewer Overflow Regulation System to Optimize Wastewater Collection
The Metropolitan St. Louis Sewer District's Overflow Regulation System (ORS) project uses computer control of a wastewater collection system for the purpose of combined sewage overflow...
Sewers and Computers
The following is a description of a project performed to reduce excessive infiltration and inflow in a municipal sanitary sewer system and to provide the municipality with a computerized...
Modeling Initial Mixing of Ocean Wastewater Discharges to Develop Toxic Effluent Limitations
The UM model, released by USEPA in 1992, was utilized to simulate the initial mixing of a discharge to the Atlantic Ocean near Ocean City, New Jersey. The study included field verification...
Modeling Settlements of an Existing Municipal Solid Waste Landfill Sideslope Using an Earthen Surcharge Pile
This paper discusses the results of a large-scale field compressibility test completed on municipal solid waste (MSW). The test consisted of surcharging the waste mass with an earthen...
Control of Microbial Water Quality in the Little Rock, Arkansas Distribution System
Beginning in the summer of 1993, seasonal studies were undertaken to evaluate the effectiveness of water treatment processes at Little Rock Municipal Water Works (LRMWW). Two treatment...
Meeting 503 Regulations for Ten Biosolids Incinerators (And Associated Stories)
This paper provides an overview of the Hampton Roads Sanitation District's Part 503 regulations compliance program regarding incineration of biosolids at five of its treatment facilities....
Modifying One of the Nation's Most Successful Biosolids Lime Stabilization Operations
Since 1978, the Vallejo, California, Sanitation and Flood Control District has managed a tremendously successful biosolids program consisting of lime stabilization and agricultural land...
Evaluating Activated Sludge Secondary Clarifier Performance: A Protocol
To establish a consistent methodology for evaluating secondary clarifier performance, the ASCE Clarifier Research Technical Committee prepared procedural guidelines in the form of a draft...
Sludge Hopper Design for Activated Sludge Clarifiers
Only in the past few years has any attention been allocated to the transport characteristics of sludge collectors. However, no attention has been given to a design rationale for the sludge...
Evaluation of Fe oxide-coated GAC for removal and recovery of Cu(II) from water
A composite solid, prepared by precipitating an Fe oxide onto granular activated carbon (GAC), was evaluated as an adsorbent for the removal and recovery of Cu(II) from water. Relative...
Sensitized Photooxidation of Dissolved Sulfides in Water
The ability of methylene blue (MB) and riboflavin (RF) to sensitize dissolved sulfides for photooxidation was investigated. Both MB and RF were found to be effective sensitizers for the...
A Coupled Mass Transfer and Surface Complexation Model for Uranium (VI) Removal from Wastewaters
A remediation technique has been developed for removing uranium (VI) from complex contaminated groundwater using flake chitin as a biosorbent in batch and continuous flow configurations....
Effect of Sludge Blend on Dewatering Characteristics
This study compares the performance of high solids centrifuges when processing anaerobically digested and undigested mixture of primary sludge and waste activated sludge, in order to evaluate...