Perfobond Rib Connectors for Composite Beams
In this paper, the influence of concrete strength, transverse reinforcement and concrete dowels on the capacity of perfobond rib shear connectors is examined. Perfobond rib connector is...
Steel Panel Encased R.C. Composite Shear Walls
In order to make clear the fundamental resisting mechanisms of composite shear walls, tests are carried out on the composite unit rigid frames with various infilled shear walls. Composite...
Effects of Connections on Composite Frames
This paper summarizes the preliminary findings from an experimental and theoretical study of the influence of composite connections on frame behaviour. The first part of the work included...
The Behaviour of Reinforced Concrete Beams Manufactured with Side Profile Sheets
The paper describes in qualitative terms the fundamental principles that control the behaviour of a completely new form of construction in which reinforced concrete beams are constructed...
Joint Outfall H Relief Trunk Sewer System
The Joint Outfall 'H' Relief Trunk Sewer System consists of the construction of 11.3 kilometers (7 miles) of polyvinyl chloride lined reinforced concrete pipe varying in diameter from...
Concrete Pipe for Sanitary Sewers Corrosion Protection Update
Significant advances have been made in the last decade in the area of sanitary sewer design techniques. Some of the most important advances have been in the prediction and prevention of...
Structural Design on Ductile Iron Pipe
The thickness class designation for Ductile Iron pipe has been changed to a pressure class designation in the 1991 revision of the C150/A21.50 ANSI standard. However, the same conservative...
Estimation of Reliability Parameters for Rehabilitation of Pipelines
This paper presents fundamental principles of estimating statistical characteristics of the elements of urban underground infrastructure networks, which provides a basis of statistical...
Evaluation of a Proprietary Tape Coating Alternative for the 157 Mile Ivie Pipeline
A two part evaluation of alternative protective coating systems for the 157 mile Ivie pipeline was made. In Part I, an evaluation was made on the suitability of a proprietary tape coating...
An Evaluation of Fiberglass Pipe Made by Three Different Manufacturing Processes for use in Water Transmission Projects
Fiberglass pipe is made primarily using continuous filament wound process, discontinuous helical filament wound process, and centrifugal cast process. Some 40 countries around the world...
Reinforced and Prestressed Concrete Pressure Pipe Diagnosis
Prestressed and reinforced concrete steel cylinder pipes are used for transmission mains, water intake lines, sewers force mains. Many collapses caused by the steel cylinder attack were...
Relocating a 54-Inch Diameter Force Main without Interrupting Wastewater Flow
The City of Tampa, Florida, was faced with the challenge of relocating three segments of an old 1372 mm (54-in.) diameter reinforced concrete pipe force main, totaling nearly a mile in...
Gas Pipeline Fitness-for-Service Investigation
A delta reclamation district's plan to add significant fill on their levee caused great concern for the integrity of a critical PG&E 22-inch (559 mm) gas transmission line which...
Pipelines Crossing Highways and Railroads by Tunneling
When new pipeline construction requires the crossing of highways and railroads, a pipeline is generally installed in pipe or tunnel linear plate encasement which has been installed by...
Analysis and Design of Direct Burial Sections of San Diego County Water Authority's Pipeline 4 Extension
The pipeline 4 extension is one of the San Diego County Water Authority's Phase I projects that will run for about 13 miles. Majority of this new pipeline will be 96 inch in steel and...
Controlling Corrosion in Bridge Structures
The overall objectives of the Structures Research Area of the Strategic Highway Research Program (SHRP) were to provide methods to protect chloride-contaminated concrete components against...
Electrochemical Treatment and Protection: Lessons Learned
Corrosion is recognized today as one of the major contributors to the deterioration of steel reinforced concrete structures. Two electrochemical techniques, chloride removal and cathodic...
Selecting Bridge Protection and Rehabilitation Options
This paper describes a recently developed procedure for use by bridge engineers making protection or rehabilitation decisions for concrete bridges. The methodology determines the most...
Modified Graphite Reference Electrodes
The primary aim of this research was to investigate the feasibility of developing an improved, more reproducible, reversible, and highly voltage invariant graphite reference half cell...
Future Improvements for Design of Flexible Pavement Structures
The first set of data analyses on the National Pavement Data Base (NPDB) derived from the Long-Term Pavement Performance (LTPP) activities have been completed. The results from sensitivity...
Return to search