Steel Panel Encased R.C. Composite Shear Walls
In order to make clear the fundamental resisting mechanisms of composite shear walls, tests are carried out on the composite unit rigid frames with various infilled shear walls. Composite...
Effects of Connections on Composite Frames
This paper summarizes the preliminary findings from an experimental and theoretical study of the influence of composite connections on frame behaviour. The first part of the work included...
The Behaviour of Reinforced Concrete Beams Manufactured with Side Profile Sheets
The paper describes in qualitative terms the fundamental principles that control the behaviour of a completely new form of construction in which reinforced concrete beams are constructed...
Concrete Pipe for Sanitary Sewers Corrosion Protection Update
Significant advances have been made in the last decade in the area of sanitary sewer design techniques. Some of the most important advances have been in the prediction and prevention of...
Structural Design on Ductile Iron Pipe
The thickness class designation for Ductile Iron pipe has been changed to a pressure class designation in the 1991 revision of the C150/A21.50 ANSI standard. However, the same conservative...
Estimation of Reliability Parameters for Rehabilitation of Pipelines
This paper presents fundamental principles of estimating statistical characteristics of the elements of urban underground infrastructure networks, which provides a basis of statistical...
Evaluation of a Proprietary Tape Coating Alternative for the 157 Mile Ivie Pipeline
A two part evaluation of alternative protective coating systems for the 157 mile Ivie pipeline was made. In Part I, an evaluation was made on the suitability of a proprietary tape coating...
Gas Pipeline Fitness-for-Service Investigation
A delta reclamation district's plan to add significant fill on their levee caused great concern for the integrity of a critical PG&E 22-inch (559 mm) gas transmission line which...
Analysis and Design of Direct Burial Sections of San Diego County Water Authority's Pipeline 4 Extension
The pipeline 4 extension is one of the San Diego County Water Authority's Phase I projects that will run for about 13 miles. Majority of this new pipeline will be 96 inch in steel and...
GIS and Cost-Effectiveness of Investment Decisions
This paper describes the use of GIS as a tool for transport planners in a form that can be described as a computer-aided decision support system (DSS) process. The main aim of this process...
Controlling Corrosion in Bridge Structures
The overall objectives of the Structures Research Area of the Strategic Highway Research Program (SHRP) were to provide methods to protect chloride-contaminated concrete components against...
Modified Graphite Reference Electrodes
The primary aim of this research was to investigate the feasibility of developing an improved, more reproducible, reversible, and highly voltage invariant graphite reference half cell...
Future Improvements for Design of Flexible Pavement Structures
The first set of data analyses on the National Pavement Data Base (NPDB) derived from the Long-Term Pavement Performance (LTPP) activities have been completed. The results from sensitivity...
Cathodic Protection for Protecting Prestressed Concrete
Due to the good effect of corrosion protection of reinforcing steel bars, even in concrete highly chloride contaminated, cathodic protection for concrete structure now carried out as a...
Influence of Lateral Wind on Driving on Offshore Bridge
The Honshu-Shikoku Bridges are a system of highways crossing over the sea, where cross-winds variously affect vehicle behaviour. This is the intermediate report on the surveys aimed at...
Changes to the AASHTO Guide for Design of Pavement Structures
At this juncture of the SHRP-LTPP program, it is appropriate to discuss the potential impacts that SHRP-LTPP results could have on the future AASHTO Guides for the Design of Pavement Structures....
Rehabilitation/Upgrading of Under-Rated or Deteriorating Single or Multi-Span Structures Using Corrugated Steel Pipe, Tunnel Liner Plate or Structural Plate
This paper cites advantages of the rehabilitation/upgrading of under-rated or deteriorating culverts or bridges using corrugated steel pipe, tunnel liner plate or structural plate. Among...
Steel Exoskeleton Defines Architecture
The Hotel de las Artes multi-use complex in Barcelona, Spain consists of a luxury hotel/apartment tower, a commercial office building, retail, parking and other amenities. The most prominent...
Nondestructive Testing Role in Repair and Rehabilitation of Concrete Structures
Nondestructive testing (NDT) methods are increasingly being used to assess the condition of structural concrete. The paper discusses applications of NDT methods for forensic investigation...
Assessment and Repair of Fire-Damaged Concrete Structures
Concrete, even though it may be the most fire-resistant of all the major building materials, can be damaged by fire. Seldom does even a major fire cause total destruction, however, most...
Return to search