Behavior of Concrete-Filled Steel Tubular Three-Dimensional Subassemblages
Three-dimensional subassemblages consisting of a concrete-filled steel tubular column and four H-shaped beams were tested under a constant axial load on the column, constant beam loads...

Application and Recent Development of a Numerical Model for Composite Beams with Partial Shear Connection
This paper deals with numeric analysis of composite steel and concrete beams for loads up to the ultimate beam capacity. Two versions of a numerical model are presented addressing such...

Influence on Steel Deck on Composite Beam Strength
Results of a recent study were described in which 7 push-out tests and 4 composite beam tests were conducted. The results were consistent with other recent studies reported in the literature,...

Composite Beams with Headed Studs in Narrow Ribbed Metal Deck
This paper presents the results of sixteen push-out tests conducted to study the behavior of headed stud connectors in composite beams with narrow ribbed metal deck placed parallel to...

Composite Walling
This paper describes a study into a system of walling that comprises two skins of profiled steel sheeting infilled with concrete. During construction the steel sheeting acts as permanent...

Numerical Analysis of Composite Slab Behavior
A new calculation procedure is described which provides an alternative to full-scale testing for composite slabs with ribbed decking used in buildings. This procedure consists of combining...

The Definition of a Short Composite Column
A `short' column in composite construction is defined as one which can be designed for its cross-section strength alone without the need to consider stability effects. An extensive study...

Strength Deterioration Behavior of Concrete-Filled Steel Tubular Beam-Columns
Cantilever beam-columns of steel square hollow section with or without filled-concrete were tested under constant axial load and alternately repeated horizontal load to investigate the...

Force Transfer in Composite Columns
The force transfer from steel to concrete without mechanical transfer devices in composite columns at points of load introduction is studied. A mechanism of force transfer and the factors...

New Steel Beam to Composite Column Connection Detail
Composite columns consisting of hollow steel tubes filled with high strength concrete with compressive strength exceeding 10000 psi (69 MPa) are being used in high-rise buildings. Connecting...

Behavior of Unbonded Braces Restrained by Reinforced Concrete and FRP
A new composite steel brace called an unbonded brace (UB) is proposed to enhance the capacity of a steel brace to carry a compressive load of almost up to the yield strength of the steel...

Perfobond Rib Connectors for Composite Beams
In this paper, the influence of concrete strength, transverse reinforcement and concrete dowels on the capacity of perfobond rib shear connectors is examined. Perfobond rib connector is...

Steel Panel Encased R.C. Composite Shear Walls
In order to make clear the fundamental resisting mechanisms of composite shear walls, tests are carried out on the composite unit rigid frames with various infilled shear walls. Composite...

Effects of Connections on Composite Frames
This paper summarizes the preliminary findings from an experimental and theoretical study of the influence of composite connections on frame behaviour. The first part of the work included...

The Behaviour of Reinforced Concrete Beams Manufactured with Side Profile Sheets
The paper describes in qualitative terms the fundamental principles that control the behaviour of a completely new form of construction in which reinforced concrete beams are constructed...

Ovality in Pipe Rehabilitation Design
Pipes in need of structural rehabilitation often have longitudinal cracks (at the crown and elsewhere) and exhibit significant ovality (5-10%). When these pipes are lined with current...

Townsite Lateral-Stage 2 Belle Fourche Unit - Cheyenne Division Concrete: Pipe with Dumped Bedding and Embedment
In 1933, M. G. Spangler presented three bedding configurations and the concept of a bedding factor to relate the supporting strength of buried concrete pipe to the strength obtained in...

Concrete Pipe for Sanitary Sewers Corrosion Protection Update
Significant advances have been made in the last decade in the area of sanitary sewer design techniques. Some of the most important advances have been in the prediction and prevention of...

Structural Design on Ductile Iron Pipe
The thickness class designation for Ductile Iron pipe has been changed to a pressure class designation in the 1991 revision of the C150/A21.50 ANSI standard. However, the same conservative...

Estimation of Reliability Parameters for Rehabilitation of Pipelines
This paper presents fundamental principles of estimating statistical characteristics of the elements of urban underground infrastructure networks, which provides a basis of statistical...

 

 

 

 

Return to search