Inelastic Seismic Analysis of Concrete Buildings
The important inelastic analysis techniques that are suitable for concrete buildings subjected to earthquakes are summarized. Basic principles and practical modeling guidelines are given...

Residual Capacity of Explosively Damaged Reinforced Concrete Columns
The results of load tests on explosively damaged reinforced concrete columns are presented. The method used to correlate an ultimate strength, laminar type of reinforced concrete analysis...

Structural Resistance of Slabs for Blast Loading
Results from a series of static tests on one-way reinforced concrete slabs are summarized. The slabs were loaded with a uniform pressure and tested to large deflections. Parameters varied...

Cracking the Fire Code
Local building codes specify fire resistance for members in buildings and other structures, and structural engineers select materials and assemblies that have passed a standard fire resistance...

Site Characterization of Yorktown Formation for New Accelerator
The design of a new 1700-m long continuous-wave electron beam accelerator facility (CEBAF) in Newport News, Virginia demanded an extensive geotechnical exploration program be conducted...

Pressuremeter Evaluation of Glacial Till Bearing Capacity in Toronto Canada
Glacial tills were evaluated at three Toronto sites, using conventional methods, the pressuremeter and full scale caisson load tests. The geologic environment and specific subsurface conditions...

Location of Geologic Discontinuities by Geophysical Techniques
An overview of the seismic refraction method and resistivity methods is given. These two geophysical techniques are integrated into a systematic method for locating geologic discontinuities...

Screw Plate Test for Drained and Undrained Soil Parameters
This paper describes a screw plate test device developed with a capability to measure the generation and dissipation of excess pore water pressure during testing in cohesive soils. The...

An Evaluation of Pile Design in Fraser River Delta Using In-Situ Tests
Modern methods of pile design often take advantage of in-situ test data. Thirteen axial pile capacity design methods have been evaluated using the results from eight full-scale pile load...

Cyclic Behavior of Natural Overconsolidated Clay in Two Loading Modes
One-way, stress-controlled, cyclic triaxial compression tests were conducted on a heavily overconsolidated (Ko > 1), slickensided, natural clay with a view to modeling its cyclic...

First-Order Estimation of Ko in Sands and Clays
The in-situ horizontal stress coefficient (Ko) is known to be the dominant design parameter controlling the side resistance of deep foundations....

Identification and Characterization of the Collapsing Alluvial Soils of the Western United States
Suggested procedures for the identification and characterization of the collapsing alluvial fan, mudflow and debris flow deposits of the arid and semi-arid parts of the western United...

Characterization of a Site Underlain by Deep Collapsing Soils
The geomorphic setting of a site underlain by an 80 ft (24 m) deep deposit of collapsing silty sand is described. The field and laboratory investigation completed to characterize the geotechnical...

Helical Bearing Plate Foundations for Underpinning
Helical anchor foundations have been used in construction to provide resistance against uplift and compressive loading for structures such as transmission towers, tied walls, pipelines,...

Power Pole Foundations in Reclaimed Mining Area
In central Florida, where strip mining for phosphate ore is a primary industry, street surfaces often become rolling because of differential settlement, and electrical transmission poles...

Jet Grout Stabilization of Peaty Soils Under a Railway Embankment in Italy
The construction of two railway embankments on a peaty soil deposit up to 7m thick required a foundation improvement program meeting very strict specifications in terms of environmental...

Settlement Characteristics from Insitu Tests in Flyash Structural Fills
Flyash from the Baltimore Gas and Electric Company's plants was used to construct structural fills in thickness ranging from 5 to 25 feet (1.5m to 7.6m). Several warehouses...

Rock Excavations in Downtown Toronto
The geology of Toronto area is somewhat complex due to the series of advances and retreats of the glaciers. The overburden deposits consist of materials laid down during the Wisconsinan...

Rock Excavation with Microwaves: A Literature Review
Research on the use of microwaves for breaking rocks started in the late fifties. In this paper, the principles of microwave heating and the possible mechanisms responsible for the breaking...

Static Behavior of Piles in Cemented Calcareous Sands
A series of instrumented jacked model pile tests and another series of uninstrumented grouted model pile tests in a cemented calcareous sand were performed. The influence of pile installation...

 

 

 

 