Seismic Safety Regulation of Existing Structures
Establishment of standards for seismic strengthening of existing buildings has been difficult since full compliance with current codes is generally too expensive. A general consensus has...

Historic Background of Seismic Construction in San Francisco
A seismic design and construction tradition has developed in California because of the unique experience with local earthquakes. After the 1906 earthquake and fire, building performance...

Equating Dynamic Analysis to Static Code Provisions
Building codes generally prescribe seismic design provisions that include a static lateral force procedure that can easily be combined with the gravity loads to design the structural elements....

Development of Inelastic Reduction Factors to Provide an Elastic Design Procedure
R factor values can only be rationally selected when they are based on in part nonlinear inelastic dynamic analyses of building system types. However, it is informative to discuss the...

1988 SEAOC and UBC Seismic Provisions
This paper highlights the major improvements to seismic design provisions incorporated in the 1988 Structural Engineers Association of California (SEAOC) 'Blue Book'...

Recent Developments in Testing Base Isolation Systems
One of these developments has been the ability to test large scale isolation systems using simulated seismic loads. These tests have not only proven the performance and reliability of...

Recent Developments in Isolation Hardware
Most isolation systems have at least two physical components: one specifically intended to add flexibility and the other to control the resulting deflections. However, other elements may...

Seismic Isolation of Nuclear Plants: A World Overview
The French were first to apply seismic isolation to the design of nuclear structures. Two large Pressurized Water Reactor plants (PWR) were isolated; the two unit Koeberg station in South...

Shake Table Testing of a Friction Pendulum Seismic Isolation System
Building models using the Friction Pendulum System (FPS) were tested on the shaking table at the Earthquake Engineering Research Center of the University of California, Berkeley. This...

Response of Concrete Buildings to Lateral Forces
ACI-ASCE Committee 442 (Response of Concrete Buildings to Lateral Forces) has just issued its report (ACI-ASCE 442 1988a). In that Report, the performance of reinforced concrete buildings...

Inelastic Seismic Design of Concrete Structures
This paper provides an overview of the state-of-the-art publication on the same subject under preparation by ASCE-ACI Committee 442's Ad Hoc Subcommittee on Inelastic Response...

Inelastic Seismic Analysis of Concrete Buildings
The important inelastic analysis techniques that are suitable for concrete buildings subjected to earthquakes are summarized. Basic principles and practical modeling guidelines are given...

Deformability of Reinforced Concrete Members
A large volume of test data has been evaluated to establish deformability of reinforced concrete beams, columns, and structural walls in the inelastic range. Experimentally observed deformation...

Residual Capacity of Explosively Damaged Reinforced Concrete Columns
The results of load tests on explosively damaged reinforced concrete columns are presented. The method used to correlate an ultimate strength, laminar type of reinforced concrete analysis...

Structural Resistance of Slabs for Blast Loading
Results from a series of static tests on one-way reinforced concrete slabs are summarized. The slabs were loaded with a uniform pressure and tested to large deflections. Parameters varied...

Cracking the Fire Code
Local building codes specify fire resistance for members in buildings and other structures, and structural engineers select materials and assemblies that have passed a standard fire resistance...

Site Characterization of Yorktown Formation for New Accelerator
The design of a new 1700-m long continuous-wave electron beam accelerator facility (CEBAF) in Newport News, Virginia demanded an extensive geotechnical exploration program be conducted...

Pressuremeter Evaluation of Glacial Till Bearing Capacity in Toronto Canada
Glacial tills were evaluated at three Toronto sites, using conventional methods, the pressuremeter and full scale caisson load tests. The geologic environment and specific subsurface conditions...

Location of Geologic Discontinuities by Geophysical Techniques
An overview of the seismic refraction method and resistivity methods is given. These two geophysical techniques are integrated into a systematic method for locating geologic discontinuities...

Screw Plate Test for Drained and Undrained Soil Parameters
This paper describes a screw plate test device developed with a capability to measure the generation and dissipation of excess pore water pressure during testing in cohesive soils. The...

 

 

 

 

Return to search