Seismic Isolation of the USC University Hospital
This paper provides an overview of the various structural engineering tasks that are associated with the implementation of the design of a seismically isolated structure. The project is...
Seismic Isolation for the Los Angeles County Fire Command and Control Facility
The use of seismic isolation is becoming an increasingly important consideration in improving the earthquake lifelines of a community. This paper identifies the major problems encountered...
The Application of Seismic Isolation to Bridges
Unlike a building application the primary intent in a bridge is to protect the structure below the plane of isolation - the superstructure being relatively rigid to in-plane loads and...
Development of Design Requirements for Seismically Isolated Structures
This paper provides background and describes on-going work by the Structural Engineers Association of California (SEAOC) to develop design requirements for seismically isolated structures....
Seismic Strengthening of a Historic Unreinforced Masonry Building
The building involved is a four-story unreinforced masonry structure. Considerations related to development of design criteria are presented along with retrofitting strategies. The building...
1988 Provisions for Masonry Design
The 1988 Uniform Building Code has seen a significant change in the seismic design requirements, Chapter 23, for the design of structures subjected to earthquake loads. This paper discusses...
Development of Inelastic Reduction Factors to Provide an Elastic Design Procedure
R factor values can only be rationally selected when they are based on in part nonlinear inelastic dynamic analyses of building system types. However, it is informative to discuss the...
Recent Developments in Testing Base Isolation Systems
One of these developments has been the ability to test large scale isolation systems using simulated seismic loads. These tests have not only proven the performance and reliability of...
Seismic Isolation of Nuclear Plants: A World Overview
The French were first to apply seismic isolation to the design of nuclear structures. Two large Pressurized Water Reactor plants (PWR) were isolated; the two unit Koeberg station in South...
Response of Concrete Buildings to Lateral Forces
ACI-ASCE Committee 442 (Response of Concrete Buildings to Lateral Forces) has just issued its report (ACI-ASCE 442 1988a). In that Report, the performance of reinforced concrete buildings...
Inelastic Seismic Design of Concrete Structures
This paper provides an overview of the state-of-the-art publication on the same subject under preparation by ASCE-ACI Committee 442's Ad Hoc Subcommittee on Inelastic Response...
Deformability of Reinforced Concrete Members
A large volume of test data has been evaluated to establish deformability of reinforced concrete beams, columns, and structural walls in the inelastic range. Experimentally observed deformation...
Residual Capacity of Explosively Damaged Reinforced Concrete Columns
The results of load tests on explosively damaged reinforced concrete columns are presented. The method used to correlate an ultimate strength, laminar type of reinforced concrete analysis...
Structural Resistance of Slabs for Blast Loading
Results from a series of static tests on one-way reinforced concrete slabs are summarized. The slabs were loaded with a uniform pressure and tested to large deflections. Parameters varied...
Reevaluation of Reinforced Concrete Slabs Subjected to Blast Effects
Failures in reinforced concrete shallow-buried structures subjected to the effects of severe dynamic loads are reevaluated by employing a modified Timoshenko beam formulation which includes...
Assessment of Transmission Line Foundations
Electric utilities are faced with the need to build new transmission lines or to upgrade existing lines to meet future demands. Because of economic constraints and the difficulty of obtaining...
Cracking the Fire Code
Local building codes specify fire resistance for members in buildings and other structures, and structural engineers select materials and assemblies that have passed a standard fire resistance...
The Church on Stilts
Christ Church Cathedral is an Anglican church situated in the heart of downtown Montreal. Constructed in 1859, it is a perfect example of English neogothic architecture, characterized...
Pressuremeter Evaluation of Glacial Till Bearing Capacity in Toronto Canada
Glacial tills were evaluated at three Toronto sites, using conventional methods, the pressuremeter and full scale caisson load tests. The geologic environment and specific subsurface conditions...
An Evaluation of Pile Design in Fraser River Delta Using In-Situ Tests
Modern methods of pile design often take advantage of in-situ test data. Thirteen axial pile capacity design methods have been evaluated using the results from eight full-scale pile load...