Recent Improvements in the LLNL PSHA Methodology
For the purpose of comparison, the LLNL PSHA methodology is defined as the 1989 version developed under contract for the NRC. Additional work on a series of subsequent projects for DOE...
Fundamental Issues in Seismic Safety in Midwestern U.S. Due to Hazard/Vulnerability Relation
Problems in establishing and mitigating seismic risk in urban areas when seismicity is not confidently based on instrumental records are discussed. Urban Southwestern Ohio is a specific...
Seismic Standards for Existing Federally Owned and Leased Buildings
Public Law 101-614 requires the Interagency Committee on Seismic Safety in construction to develop 'standards for assessing and enhancing the seismic safety of existing buildings constructed...
Nonlinear Response of SDOF Systems to Intraplate Earthquakes
It is well established that there are characteristics differences between intraplate and interplate earthquakes. A parametric study of SDOF systems indicates that there is also consistent...
Connectors for Earthquake Resistant Structures
Damage assessments from the past several earthquakes located on the northern, central and southern zones of the San Andreas Fault - Cape Mendocino: April 1992, 7.1; Loma Prieta: October...
The European Approach to Seismic Design of Engineered Timber Constructions: The Case of Low-Dissipative Structures
In the present paper the importance of the dissipated energy on the actual structural behaviour of low-dissipative structures as glulam portal frames with mechanical fasteners under seismic...
Wind Design and Analysis for the Normandy Bridge
The Normandy Bridge will represent an important progress in the field of cable-stayed bridges, with a main span 856-metre long. This paper explains how the design has been oriented to...
Wind Tunnel Testing for the Great Belt East Suspension Bridge
This paper provides an overview of model tests conducted to study and predict the aerodynamic behavior of the proposed streamlined box-girder suspension bridge for the Great Belt Link....
Prediction of Wind-Induced Responses and Wind Loads
The Recommendations for Wind Loads of Buildings and Structures of the Architectural Institute of Japan have now been updated. This paper presents the drafts of the new Recommendations...
Wind Resistant Design and Response Control of Tall Building
This paper presents an overall view of the wind resistant design and response control of the tall buildings in Japan, the Crystal Tower in Osaka and the Landmark Tower in Yokohama. The...
Wind Resistant Design Manual for Highway Bridges
'Wind resistant design manual for highway bridges in Japan' has been published in 1991. Before publication of this manual, there were no authorized wind resistant manuals which can be...
Bridge Aerodynamics and Response Control?Recent Research and Developments in Japan
Bridge aerodynamics and its response control with emphasis on the recent R/D in Japan are reviewed. Aerodynamic countermeasures based on the vibration mechanisms as well as mechanical...
Investigation of a Failed Concrete Joist System
The failure and distress of concrete joists contained in the promenade roof deck of a one-story, college, lecture hall building initiated an extensive investigation to determine the cause...
Current Forensic Courses in Civil Engineering
The ASCE is taking a leadership role in the prevention of failures of engineered facilities. The Technical Council on Forensic Engineering Education Committee recently completed a survey...
Tuned Mass Damper in Tall Building Design
Viscoelastic dN and tuned mass dampers are often used by tall building designers to control wind-induced building vibrations resulting from such phenomena as vortex shedding, galloping,...
A California Tower: Response to Seismic Forces
First Interstate World Center is a signature building for the city of Los Angeles. The granite clad tower with its serrated facade rises 1,018 ft. above street level. It is the tallest...
Seismic Behavior of High Strength Concrete Columns
Information on the ductility of high strength columns in seismic areas has been scarce. The available information is based mainly on small test columns subjected to monotonic concentric...
Tuned Mass Dampers for Towers and Buildings
Tuned mass dampers (TMD's) are used to reduce the response of tall slender structures to resonant wind-induced oscillations. This paper reviews the authors' experience with the design...
Structural Design and Wind Resistance of Fukuoka Tower with T.M.D.
Fukuoka Tower, which was built in 1989, was projected as a monument, a observation tower and a broadcasting antenna with 234m high. In this tower, a Tuned Mass Damper(TMD) was set, in...
Long-Span Design for Seismic Forces?A Case Study of the Anaheim Arena
The design for the Anaheim Arena roof evolved in response to the strict requirements for a structure in a seismic zone 4 location. The support of the 329 ft. (100 m) by 444 ft. (135 m)...