Pressuremeter Evaluation of Glacial Till Bearing Capacity in Toronto Canada
Glacial tills were evaluated at three Toronto sites, using conventional methods, the pressuremeter and full scale caisson load tests. The geologic environment and specific subsurface conditions...

An Evaluation of Pile Design in Fraser River Delta Using In-Situ Tests
Modern methods of pile design often take advantage of in-situ test data. Thirteen axial pile capacity design methods have been evaluated using the results from eight full-scale pile load...

Ground Modification for a 14-Story Structure Over a Deep Peat Deposit
The foundation design and construction for a 14-story reinforced concrete office building northwest of Minneapolis is described. The building's geometry provided unusual foundation...

Model Tests for Bearing Capacity of Vertically Reinforced Foundations in Sand
Laboratory model test results for the bearing capacity of strip foundation supported by a sand layer with semi-flexible vertical rod reinforcements have been presented. All test results...

The Influence of Cyclic Loading on the Lateral Load Response of Groups of Piles
The effects of cyclic loading on the lateral response of closely spaced groups of piles has been widely considered to be a single pile phenomenon, related to gapping and scour around the...

Ultimate Capacity of Deep Foundation by a Rigid-Plastic Analysis
This paper is concerned with the determination of the axial ultimate capacity of a rigid pier on the basis of the theory of perfect plasticity. As an application of the upper bound theorem...

Seismic Response Considerations in Foundation Design
There are no generally accepted procedures to determine the potential magnitude of reduction of footing bearing capacity that may result from soil strains or pore pressure changes during...

Risk Correction Factors for Bearing Capacity Analysis
In this paper bearing capacity correction factors are developed to account for the randomness in the load and soil properties. These are applied to the bearing capacity equation in the...

Geotechnical Judgment in Foundation Design
This paper summarizes the initial findings of a research project to investigate the judgment-making process of foundation engineers. Solutions for a typical design problem were solicited...

Comparative Performance of Two Pile Types
This paper reports on the pile driving and load bearing characteristics of the two pile types driven at a plant site in Sumatra, Indonesia. Nine prestressed concrete piles were driven...

Contribution of Soil Freeze to Pile Capacity
In order to investigate the magnitude and rate of increase in load capacity for piles installed in clayey soils, a series of load tests were performed at various intervals of time following...

New Design Method for Drilled Shafts from Common Soil and Rock Tests
A method is presented by which the compressive capacity and load-settlement characteristics of large drilled shafts can be computed from commonly executed soil and rock tests. The method...

Performance of High Capacity Caissons Founded on Decomposed Rock
The results of six load tests on large diameter caissons founded on decomposed rock are presented and analyzed. The caissons ranged from 1.5 m to 2.5 m in diameter and were 20 m to 23...

Full Scale Caisson Load Test for the Milwaukee Center
Top-down procedures were proposed to construct four basement levels for a major high-rise building development in Milwaukee, Wisconsin. Drilled caisson foundations were the preferred means...

Drilled Shafts?A Database Approach
A database of 43 drilled shaft load tests of high quality has been developed to study parameters that affect the axial behavior of drilled shafts and methods of analysis to predict axial...

A Lateral Load Test on Seven Foot Diameter Caissons
Seven foot (2.1 m) diameter caissons (drilled shafts) were designed to support a mainline eastbound bridge and an off-ramp of Interstate Highway 70 in Glenwood Canyon, Colorado. A lateral...

Bearing Capacity of Shallow Strip Foundation on Strong Clay Underlain by Weak Clay
Laboratory model test results for the ultimate bearing capacity of shallow strip foundations supported by a stiff clay layer underlain by a weaker clay layer have been presented. The model...

Effect of Void on Footing Behavior Under Eccentric and Inclined Loads
The effect of underground void on the behavior of strip footings subjected to eccentric and inclined loads was investigated using the finite element method of analysis. Results of the...

Bearing Capacity of Shallow Foundation on Granular Column in Weak Clay
Laboratory model tests results for the ultimate bearing capacity of shallow rectangular foundations supported by granular columns made in weak clay have been presented. In all cases, the...

Combination Drilled Shaft and Driven Pile Foundation for a High-Rise Building
A case history is presented which discusses the design and construction of a combination drilled shaft and driven pile foundation which supports a high-rise in San Francisco. Drilled piers,...

 

 

 

 

Return to search