Thermal Shielding in Continuous Span Composite Slabs
The increasing popularity in Europe of composite slabs with cold-formed steel decking has underscored the need to improve calculation rules for the fire resistance. Existing rules have...

A Simple Finnish Method for the Structural Fire Design of Composite Structures
The structural fire design of composite structures in Finland has previously been based on furnace tests, which are expensive and take too much time to arrange. With the increasing prominence...

Summary Report Design Session
The Tuesday presentations were devoted to design. Eight papers were presented in the morning general session and 17 presentations were made in 4 concurrent evening workshops. Diversity...

Design of Composite Slabs for Vertical Shear
Three major modes of failure should be considered in the design of the positive moment regions of composite slabs incorporating profiled steel sheeting, viz.: flexure, longitudinal slip...

Ductility Effects of End Details in Composite Beams
A limit states criterion is described for quantifying the rotation capacity of members in indeterminate structures as a means of classifying ductility of structures during plastic behaviour...

Development of Composite Slab with Truss-Typed Shear Connectors
This paper describes the results of the test on a steel-concrete composite slab with truss-typed shear connectors. This composite slab was recently developed. A series of tests were conducted...

A New Method from China to Determine Load-Carrying Capacity for CFST Members
The most common research method for CFST (concrete-filled steel tubular) members is to study the behaviors of the steel tube and the core concrete separately, then add them together to...

Strength and Stiffness Behavior of Composite Steel Grid Decks
This paper briefly discusses the historical development of composite steel grid decks. The static and fatigue behavior under bending of filled and unfilled steel grid decks (exodermic)...

Proposal on Story Drift Limit Based on Axial Behavior of Column under Seismic Loads
The main function of columns primarily is to support axial loads both under and after repeated lateral loading from earthquakes. A definition of the story drift limit in any structural...

Behavior of Concrete-Filled Steel Tubular Three-Dimensional Subassemblages
Three-dimensional subassemblages consisting of a concrete-filled steel tubular column and four H-shaped beams were tested under a constant axial load on the column, constant beam loads...

Influence on Steel Deck on Composite Beam Strength
Results of a recent study were described in which 7 push-out tests and 4 composite beam tests were conducted. The results were consistent with other recent studies reported in the literature,...

Numerical Analysis of Composite Slab Behavior
A new calculation procedure is described which provides an alternative to full-scale testing for composite slabs with ribbed decking used in buildings. This procedure consists of combining...

Strength Deterioration Behavior of Concrete-Filled Steel Tubular Beam-Columns
Cantilever beam-columns of steel square hollow section with or without filled-concrete were tested under constant axial load and alternately repeated horizontal load to investigate the...

Perfobond Rib Connectors for Composite Beams
In this paper, the influence of concrete strength, transverse reinforcement and concrete dowels on the capacity of perfobond rib shear connectors is examined. Perfobond rib connector is...

Effects of Connections on Composite Frames
This paper summarizes the preliminary findings from an experimental and theoretical study of the influence of composite connections on frame behaviour. The first part of the work included...

The Behaviour of Reinforced Concrete Beams Manufactured with Side Profile Sheets
The paper describes in qualitative terms the fundamental principles that control the behaviour of a completely new form of construction in which reinforced concrete beams are constructed...

The Pipe/Soil Stiffness Ratio Variable
This paper reviews the factors which affect the reactions and defines performance limitations of buried flexible plastic pipe as a function of load-induced strains and deflections. The...

Ovality in Pipe Rehabilitation Design
Pipes in need of structural rehabilitation often have longitudinal cracks (at the crown and elsewhere) and exhibit significant ovality (5-10%). When these pipes are lined with current...

Sliplining: Design and Installation Considerations for Polyethylene Pipe
The design methodology and installation procedure for polyethylene slipline renewal are discussed. When designing there are two critical phases which must be considered: (1) short-term...

Microtunneling with PVC Pipe
PVC is a suitable and economical product for sewer system construction. However, in the past, utilization of PVC sewer pipe in microtunneling was impossible due to axial thrust load limitations...

 

 

 

 