Advances in Trenchless Sewer System Reconstruction
The new developments and refinements in trenchless reconstruction technologies now permit total sewer system rebuilding of collectors, interceptors, manholes, service laterals, and force...
Review of PIM (Pipeline Insertion Method) Technology
The U.S. Army Construction Engineering Research Laboratory (USACERL) conducted the first demonstration of PIM (Pipeline Insertion Method, formerly Pipe Insertion Machine) technology for...
Investigation & Rehabilitation of Seattle's Tolt Pipeline
Seattle Water Department's Tolt Pipeline brings water 24 miles from storage in the Cascade Mountains into city and suburban distribution systems. Twenty-three miles of this...
Column Separation in Pumped Pipelines
Pressure transients are common occurrences in water supply systems. Pipeline standards and design/testing techniques will normally provide sufficient protection for transmission and distribution...
Comprehensive Leak Detection Survey and Benefit/Cost Analysis
Fort Carson, Colorado was the site of a comprehensive leak detection investigation of the potable water system with the express purpose of quantifying the benefits to be derived by a military...
Valve Control to Avoid Column Separation in a Pipe
Maximum pressures in a pipeline can be reduced significantly by closing the valve in an optimal manner. Such an optimal valve closure policy may result in some situations in minimum pressures...
Geometrical Nonlinearity in Offshore Pipelines
Pipelines are very flexible structural systems which are subjected to various boundary conditions. For instance, during the laying process, the pipes roll on the guidance tracks on the...
Next Stop: The Los Angeles Metro Rail
The Los Angeles Metro Rail is a $6.5 billion light and heavy rail system, which may be entirely completed by the year 2000. A 22 mi segment of the 150 mi light rail system, connecting...
Whatever Happened to Long-Term Bridge Design?
The Chairman of the Board of one of the leading engineering firms in the nation ponders the future of American bridges. In today's designing of bridges, Thomas R. Kuesel points...
Seam Examination
Charron discusses the importance of seam sampling in geomenbrane installation. In 1988, about 30 million mi of polyethylene geomembranes were used to line landfills, liquid impoundments,...
Design of Ductile Iron Pipe on Supports
Design procedures for ductile iron pipe in normal underground service have been well established. The standard design considers hoop stresses in the pipe wall due to internal hydrostatic...
Anchorage Sewer Rehabilitation in Campbell Lake
This paper discusses the proposed rehabilitation/replacement of the Campbell Lake portion of the Campbell Creek C-5 Trunk Sewer (C-5 Trunk) located in Anchorage, Alaska. The original corrugated...
Whitfield Reservoir Inlet Outlet Pipeline
Alameda County Water District reports on the planning, design and construction of a 48-inch water main installed under modern urban circumstances. The location of the pipe and the construction...
Cheyenne Stage II Water Delivery Pipeline and Shoshone Municipal Water Supply Pipeline
This paper deals with the design and construction aspects of two pipeline projects in Wyoming. Located in southeastern Wyoming, the Cheyenne Stage II Water Delivery Pipeline consists of...
Optimal Design of Water Transmission Mains
Capital cost for constructing a water transmission main includes cost of the pipeline and its associated installation costs. Also included in the capital cost is the cost of a pump station....
Analysis of Alternative Pipe Materials for a Major Public Water Agency
A major southwestern public water agency has historically specified the exclusive use of prestressed concrete cylinder pipe (PCCP) for large diameter water transmission mains. Due to the...
Life Cycle Cost Analysis Discount Rates and Inflation
Life Cycle Cost Analysis techniques are useful for comparing alternatives that have differing cash flows over the expected life of a project. The selection of an appropriate discount rate...
Twin Pipeline Crossing of the Fraser River
A new creek water supply was developed for the communities of Mission and Matsqui, British Columbia, Canada, in the early eighties. Over 60 kilometres of 450 mm to 900 mm diameter ductile...
Evaluation and Selection Methodology for Determination of a Preferred Pipeline Alignment
The San Diego County Water Authority (SDCWA) had need to construct a regional 108 to 72 inch (2.7 to 1.8 meter) diameter pipeline through San Diego County to increase water supply to its...
Field Experiment on Behavior of Continuous Water Main with a Miter Bend
A field experiment was conducted to investigate behaviors of a buried continuous steel water main with a 90-degree miter bend subjected to internal pressure and ground settlement. Deformations...
Return to search