Outlet Structure Hydraulics
Current detention basin design procedure is to design the outlet structure for two or more return periods. This is sometimes done by combining weirs and/or orifices of various sizes and...
Air-Water Oxygen Transfer at Spillways and Hydraulic Jumps
Dissolved oxygen measurements are reported for seven spillway structures in the vicinity of Minneapolis, Minnesota, corresponding to 27 individual surveys. The surveys are taken during...
On-Site Microcomputer Control of a Combined Sewer Overflow Diversion Structure
This paper describes the design of an inexpensive system for controlling combined sewer overflows using on-site equipment (raingauges, flow gauges, automatic gates, and microcomputers)....
Management Practices for Erosion and Sediment Control in Irrigated Agriculture
Basin irrigating rice can reduce suspended sediment loads in water because the basins serve as sediment retention basins. Furrow erosion causes significant suspended sediment loads in...
Verification of a Supply Reliability Model
Three versions of an analytical model for estimating the reliability of a water supply system including capacity components and small amounts of finished water storage are presented. Simplifying...
Modeling Reliability in Water Distribution Network Design
The component failures in a water distribution system include pipe breaks, pump failures, valve failures, storage malfunctions, etc. The reliability of these components has an effect upon...
Intense Storms and the Runoff Coefficient
During prolonged, intense storms the runoff coefficient increases in value and approaches one irrespective of the vegetation and soil characteristics of the watershed. As the runoff coefficient...
Unique Flood and Drainage Problems in Los Angeles
Storm drainage for the coastal cities has to traverse highly used sandy recreational beaches. Due to new requirements on the construction of storm drains to the ocean, a beach outlet has...
Computer Aided River Basin Management in the Alps
The present paper outlines progress in developing river basin management potential through joint research on several Alpine River Systems including the Avisio, Brenta, and Cordevole. Applications...
Energy Dissipation in Small Canals
Two approaches are used for energy dissipation in channels. In the first, the water is allowed to drop, thereby converting potential energy to kinetic energy. This excess energy is then...
Trash Busters ? A Comparison of Screening Structures for Irrigation Systems
Several irrigation districts in the Pacific Northwest have recently installed screening structures for use in removal of trash from canals, rivers, or reservoirs. Some of the screens have...
Guidelines for Maintenance of Aging Water Pipes
Break failure patterns are investigated by applying a new methodology based on Proportional hazards and Poisson-type models. Application on two water distribution systems of North-Eastern...
Tunneling Around Ft. McHenry
The world's largest underwater tunnel was built out of sight and sound of Ft. McHenry. The 4,000 ft tunnel needed to take I-95 from shore to shore had to be extended to 7,200...
Long Reinforced Concrete Columns
Papers selected by the Reinforced Concrete Research Council of ASCE. This collection contains 13 papers reporting the results of a series of studies,...
Reviewing for Potential Failure
The key to preventing structural failures is to examines them and develop systematic techniques for avoidance. One, called contingency analysis, starts with a what if process to decide...
Top Projects of 1986
In the 1986 ASCE competition to select the Outstanding Civil Engineering Achievement of the Year, 14 projects were nominated. This article describes the 10 non-winners. Technically the...
Financial Development for Projects
An important element in the total package of Bechtel's engineering and construction services is the financing and commercial assistance offered in support of our client's...
Restoration of Navy LTA (Lighter Than Air) Hangars
In 1942 and 1943 the Government constructed a series of 16 blimp hangars at ten Naval Air Stations along the east coast, west coast and gulf coast. The hangars erected in pairs housed...
Use of Nondestructive Testing in Rehabilitation of Wood Cooling Towers
State-of-the-art nondestructive evaluation (NDE) techniques, destructive testing, structural analysis, degradation rate models and statistical analysis are combined to optimize a major...
Decay in Wood Structures
One of the main causes of wood deterioration is decay. Decay causes millions of dollars in damage to timber structures each year. Left unchecked, decay deterioration can become a structural...
Return to search