On Reliability-Based Structural Optimization for Earthquakes
Previous studies of reliability-based structural optimization have been extended in order to investigate the applicability of the linear statistical model in cases where random parameters...
Seismic Restraint of Hazardous Process Piping
The lack of appropriate guidelines for the design and installation of hazardous process piping in industrial facilities has created a potentially dangerous situation. Process piping carrying...
Three Phase Design for Wind Loads on Structures
The successful design of a structure requires three phases of work. These phases are: conceptual design, design development and design verification. The conceptual design is undertaken...
Nonlinear Dynamic Response ofWindow Glass Plates Using Finite Difference Method
C. V. G. Vallabhan has established an efficient iterative procedure to solve the Von Karman nonlinear plate equations using finite difference method for a rectangular plate. Here the method...
Wind Loads and Building Response Predictions Using Force Balance Techniques
The use of force balance techniques to measure mean and dynamic wind loads on models of buildings and structures is discussed. Advantages of using force balance techniques over estimating...
Behaviour of Full-Scale Reinforced Concrete Structure on Realistic Foundation
A full-scale seven-story reinforced concrete building, tested as a part of U. S. -Japan Cooperative Research Program, performed well even under a severe earthquake loading condition. Nonlinear...
Modeling 3-D Response in R/C Frame-Wall Structures
As part of the recent U. S. -Japan Cooperative Research Program on the seismic performance of buildings, a 1/5-scale model of a 7-story reinforced concrete frame-wall structure, was constructed...
Seismic Behavior of a Full-Scale K-Braced Steel Frame?Part I Gross Behavior
As a part of the U. S. -Japan Cooperative Research Program Utilizing Large-Scale Testing Facilities, a six-story, 2 by 2 bay, concentrically K-braced steel building was constructed in...
Seismic Behavior of a Full-Scale K-Braced Steel Frame?Part II Local Behavior
The full-scale six-story concentrically K-braced steel building was subjected to Miyagi-Ken-Oki simulated earthquake whose peak intensity was 500gal. Local behavior of the test building...
Building Identification: Needs and Means
The need to conduct 'system identification' of existing buildings by nondestructive testing is discussed. A recommended flow-chart is exemplified. Existing dynamic...
Slab Participation in Frames under Lateral Loads
A unique opportunity to study slab participation was afforded by the U. S. -Japan Cooperative project on large scale testing. The data obtained from the full-scale 7-story building tested...
Earthquake Response Simulation Capacity of Pseudo Dynamic Testing?Experimntal Demonstration and Analytic Evaluation
The response accuracy of the pseudo dynamic test was evaluated from the shake table and pseudo dynamic tests conducted for a two story steel braced frame model. The obtained responses...
Evaluation of Seismic Strengthening of an Existing Building Using Base Isolation
This paper summarizes a study performed by Englekirk and Hart, Inc. to evaluate the feasibility of using base isolation to seismically upgrade an existing highrise building. To realize...
Dynamics of 3-D Base Isolated Structures
The work described in this paper concerns the dynamic behavior of asymmetric base isolation systems consisting of laminated rubber bearings and hysteretic dampers. It is shown in this...
The Earthquake Barrier
The earthquake barrier protects buildings from the horizontal ground vibrations of an earthquake by installing a 'force barrier and an energy barrier' at the...
Earthquake Response of Five Story Reinforced Concrete Masonry Test Building
In 1986, a full-scale five story reinforced masonry test building is to be constructed in the Japan Building Research Institute Large-Scale Structure Test Laboratory, and through 1987...
Full Scale Tests of Cladding Components
A full scale, six story, steel frame at the Building Research Institute, Tsukuba, Japan was constructed for a series of projects in the U. S. -Japan Cooperative Research Program. This...
System Identification Applied to Pseudo-Dynamic Test Data: A Treatment of Experimental Errors
A single-input single-output system identification technique, used to estimate the modal properties of a full-scale six-story steel structure tested within its elastic range by the pseudo-dynamic...
Adaptation of Modal Testing Procedure to Shaker Tables
This article presents a technique for adapting current modal testing procedures to shaker table tests commonly used for qualification tests of nuclear and space related equipment. It involves...
Problems of Spectral Analysis in Dispersion Tests
The use of dispersive surface waves and spectral analysis methods is new to the nondestructive testing of airfield pavements. Such tests are to determine whether mechanical properties...
Return to search