Seismic Behavior of Long-Span Cable-Stayed Bridges
Special features of the earthquake-response analysis of cable-stayed bridges, subjected to multiple-support excitation, are presented including a basis for calculation of seismic forces...

Seismic Response Analysis of Two Major Bridge Structures
The seismic response analyses of two major bridge structures have been conducted. In these two bridges, portions of the piles are either submerged in the water or free-standing within...

Performance of Existing Buildings: Results of Benchmark Structure Analyses Performed in U.S.-Japan Workshops
In response to the need for better understanding of current safety evaluation methodologies, three U. S. -Japan workshops have been conducted on the evaluation of the performance of existing...

Three Phase Design for Wind Loads on Structures
The successful design of a structure requires three phases of work. These phases are: conceptual design, design development and design verification. The conceptual design is undertaken...

Nonlinear Dynamic Response ofWindow Glass Plates Using Finite Difference Method
C. V. G. Vallabhan has established an efficient iterative procedure to solve the Von Karman nonlinear plate equations using finite difference method for a rectangular plate. Here the method...

Wind Loads and Building Response Predictions Using Force Balance Techniques
The use of force balance techniques to measure mean and dynamic wind loads on models of buildings and structures is discussed. Advantages of using force balance techniques over estimating...

Modeling 3-D Response in R/C Frame-Wall Structures
As part of the recent U. S. -Japan Cooperative Research Program on the seismic performance of buildings, a 1/5-scale model of a 7-story reinforced concrete frame-wall structure, was constructed...

Building Identification: Needs and Means
The need to conduct 'system identification' of existing buildings by nondestructive testing is discussed. A recommended flow-chart is exemplified. Existing dynamic...

Earthquake Response Simulation Capacity of Pseudo Dynamic Testing?Experimntal Demonstration and Analytic Evaluation
The response accuracy of the pseudo dynamic test was evaluated from the shake table and pseudo dynamic tests conducted for a two story steel braced frame model. The obtained responses...

Evaluation of Seismic Strengthening of an Existing Building Using Base Isolation
This paper summarizes a study performed by Englekirk and Hart, Inc. to evaluate the feasibility of using base isolation to seismically upgrade an existing highrise building. To realize...

Dynamics of 3-D Base Isolated Structures
The work described in this paper concerns the dynamic behavior of asymmetric base isolation systems consisting of laminated rubber bearings and hysteretic dampers. It is shown in this...

Earthquake Response of Five Story Reinforced Concrete Masonry Test Building
In 1986, a full-scale five story reinforced masonry test building is to be constructed in the Japan Building Research Institute Large-Scale Structure Test Laboratory, and through 1987...

Flexural Behavior of Reinforced Masonry Walls and Beams
Many reinforced masonry walls and beams were tested as a part of the U. S. -Japan cooperative research program on masonry building structures. Six concrete block and two clay brick masonry...

Stress-Strain Behavior of Grouted Hollow Unit Masonry
Experimental results from axial stress-strain tests including post-peak response on hollow unit masonry prisms are compared to those of previous researchers....

System Identification Applied to Pseudo-Dynamic Test Data: A Treatment of Experimental Errors
A single-input single-output system identification technique, used to estimate the modal properties of a full-scale six-story steel structure tested within its elastic range by the pseudo-dynamic...

Adaptation of Modal Testing Procedure to Shaker Tables
This article presents a technique for adapting current modal testing procedures to shaker table tests commonly used for qualification tests of nuclear and space related equipment. It involves...

Problems of Spectral Analysis in Dispersion Tests
The use of dispersive surface waves and spectral analysis methods is new to the nondestructive testing of airfield pavements. Such tests are to determine whether mechanical properties...

Optimal Collection of Data for Parameter Identification
In this paper, the author attempts to study the optimal spacing of measurements for a structural system modelled by a single-degree-of-freedom oscillator so that the variance of one or...

Research Topics in Structural Identification
The authors examined a variety of possible research topics including identification and detection of nonlinearities, model improvement approaches, damage identification, power estimation...

A Discrete Model for the Estimation of the Elastic Abutment Stiffness
The purpose of this paper is the presentation of a simple method for the estimation of the abutment stiffness. In this method, the abutment is represented as a uniform rigid plate with...

 

 

 

 

Return to search