Seismic Isolation of Storage Tanks
There has been a significant amount of research activity over the past decade on the seismic design of storage tanks. The seismic design issues and limit states are quite complex due to...

Detection of Seismic Structural Damage
Damage analysis models based on equivalent modal parameters are used to identify the serviceability limit state for structures subjected to earthquake loads. A model for the analysis of...

A Damage Model for Reinforced Concrete
The damage index developed by the authors models concrete damage as a low-cycle fatigue phenomenon. By quantifying the energy dissipated as a fraction of the total energy dissipation capacity,...

Biaxial Damage Assessment
The structural system under investigation is a frame subject to seismic excitations. The analysis accounts for the spatial distribution of beams, columns and bracing system. It also considers...

Normalized Damage Index for Evaluation of Buildings
A conceptual model for evaluation of structural damage is developed based on the fundamental idea of demand and capacity. The proposed formulation combines two recognized sources of damage:...

Seismic Vulnerability Evaluation in Japan
The state of the art in Japan is reviewed on the evaluation of the seismic capacity of existing low- to mid-rise reinforced concrete buildings, taking into account the different resistance...

Overview of Published Documents for the Evaluation of Existing Buildings
Presently, the most common procedure used by engineers to evaluate existing buildings is probably a code approach that was developed for the design of new construction. Many engineering...

Seismic Evaluation of Buildings in the Eastern and Central United States
The Applied Technology Council (ATC) has developed and published a methodology, ATC-14, for evaluating specific buildings that is tailored for use by practicing structural engineers. ATC-14...

Comparison of Slitted and Non-Slitted R. C. Shear Walls With Boundary Elements Under Horizontal Forces
This paper compares the differences of aseismic behaviours between slitted and non-slitted shear walls under horizontal forces. There are 5 specimens for slitted shear walls and another...

Effects of Semi-Rigid Connections and P-? Forces on the Optimum Design of Seismic Steel Frames
By utilizing methods of optimality critera and constraint gradients, the minimum weight design of semi-rigid planar steel frames subjected to static and seismic excitations is presented...

Amelioration of Stirrup and Compression Reinforcement on the Ductility of Reinforced High-Strength Concrete Beam
18 rectangular high strength concrete beams were tested to investigate their ductile behavior. The results show that it will be more advantageous, for ductility, to choose the compressive...

Seismic Isolation of the USC University Hospital
This paper provides an overview of the various structural engineering tasks that are associated with the implementation of the design of a seismically isolated structure. The project is...

Seismic Isolation for the Los Angeles County Fire Command and Control Facility
The use of seismic isolation is becoming an increasingly important consideration in improving the earthquake lifelines of a community. This paper identifies the major problems encountered...

Seismic Isolation of a Flight Simulator Manufacturing Facility
The corporate headquarters of Evans & Sutherland is located in the University of Utah Research Park which is in Salt Lake City, Utah. A major fault runs through Salt Lake City...

The Application of Seismic Isolation to Bridges
Unlike a building application the primary intent in a bridge is to protect the structure below the plane of isolation - the superstructure being relatively rigid to in-plane loads and...

Development of Design Requirements for Seismically Isolated Structures
This paper provides background and describes on-going work by the Structural Engineers Association of California (SEAOC) to develop design requirements for seismically isolated structures....

Retrofitting Existing Seismically Hazardous Buildings
This paper presents a brief overview of the types of problems encountered in retrofitting of existing seismically hazardous buildings. Included is a description of the various types of...

Seismic Strengthening of a Historic Unreinforced Masonry Building
The building involved is a four-story unreinforced masonry structure. Considerations related to development of design criteria are presented along with retrofitting strategies. The building...

Seismic Strengthening of a Tall Masonry Building
The design of a strengthening system for a tall building is proposed using ductile reinforced masonry shear walls. This innovative design concept produced a system that controlled the...

Study of the Seismic Behavior of Retrofitted Reinforced Concrete Buildings
Over ten years experimental research in Japan on the seismic behavior of retrofitted reinforced concrete buildings is reviewed. Emphasis is put on the improved strength and/or ductility...

 

 

 

 

Return to search