Consolidation Settlement Potential in South Louisiana
Primary consolidation is an important cause of wetland loss in active and recently abandoned deltaic plains in south Louisiana. Argillaceous and organic facies are most subject to reduction...
Vertical Erosion on Beaches and the National Flood Insurance Program
During the 25 years that the National Flood Insurance Program (NFIP) has been in existence, there has been an increasing recognition of the contribution of both episodic and long-term...
Bridge Scour Analysis in New Jersey: Which Scour Factors Matter Most?
This paper seeks to correlate the scour susceptibility of bridges with such observable characteristics as bridge design features, waterway characteristics, and geographic and geologic...
Preliminary Studies of Pressure Flow Scour
Bridges that become inundated during floods have slightly pressurized flow that impacts bridge piers and creates an aggravated scour condition. Results of two preliminary laboratory studies...
The Influence of Exposed Footings on Pier Scour Depths
Data compiled from past test efforts are combined in this article with the results of two new flume test studies. The combined material, presented graphically, suggests a method for adjusting...
Threats to Bridge Stability from Scour Related Failures of Drop Structures
Catastrophic failure of bridge foundations may occur when channel bed elevations are lowered unexpectedly. Bridges to be constructed in channels that are known to have bed degradation...
Overmining Causes Undermining(
Instream aggregate mining has caused significant problems and expense to California bridges. Riverbed degradation on the order of 3-5 m (9-15 ft) beneath waterway crossings within actively...
Uncertainty of Bridge Scour Estimates
Pier scour is the erosion of a streambed in the vicinity of bridge pier foundations. In this paper, fuzzy regression is used to develop two pier scour models, one based on crisp laboratory...
Bending of Retrofitted Test Foundation Walls
New repair methodology has been developed for residential construction that can be used to retrofit foundation bearing walls damaged by mine subsidence. The repair strengthens the foundation...
Design and Construction of the Miami Metromover Extensions
Final design, right-of-way acquisition and construction of two extensions to the existing Downtown Miami Automated People Mover, known as the Metromover, began in September 1989. Millions...
Pin Piles Save Silos
The United Grain Corp. annually ships about 200 million bushels of wheat and other grains to destinations around the world from its leased facility on the Columbia River at Vancouver,...
Use of Pressuremeter in Mixed Highrise Foundation Design
The pressuremeter has been used extensively for the evaluation of strength and deformation characteristics of the glacial hardpan soils in the design and construction of caisson foundations...
Piles for Marquette University Math Building
This paper presents a comparison of static pile capacity predictions using CPT cone resistance results with results of a test pile program and production pile driving. Pile capacity prediction...
3-D Deformation Analysis of Pile Groups During Wave Loading
Deformation predictions of pile group supporting one leg of Magnus platform were conducted using the 3-D nonlinear computer program SPLICE (Structure/Pile/Soil Interaction Analysis) and...
Evaluation and Monitoring of Pile Performance Using Dynamic Measurements in Supporting Offshore Structures
The installation of offshore platforms into deeper waters and new environments is accompanied by an increasing uncertainty in the structure response, foundation design and performance....
A Centrifuge and Analytical Study to Evaluate Suction Caissons for TLP Applications in the Gulf of Mexico
This paper documents the results of a combined centrifuge and analytical study to evaluate the behavior of steel suction caissons under loading and soil conditions typical of deepwater...
Behavior of Suction Piles in Sand
In the marine environment, use of suction pressure for the installation of sealed top piles (suction piles) is a promising alternative to driven pile foundations, particularly in deep...
Execution and Evaluation of High Capacity Caisson Load Tests in Glacial Deposits
As part of the Boston Harbor clean up project, the new 1,000 mgd Deer Island Sewerage treatment plant includes ten 240 feet high egg-shaped 'residuals' tanks. Contract documents called...
Bi-Directional Load Testing of Shafts to 6000 Tons
This paper describes the use of Osterberg cells (O-cells) to perform bi-directional load testing on full size production drilled shafts for a major bridge foundation near Owensboro, Kentucky....
Negative Skin Friction Due to Wetting of Unsaturated Soil
A steel building at a cement plant un Utah was originally supported by spread footings. Shallow wetting of the coarse granular soils supporting the footings resulted in over three inches...
Return to search