Embankment Seepage Control Design and Construction
For seepage control features of embankment dams, design criteria and construction practice is reviewed as it is reflected in the experience of the U. S. Army Corps of Engineers. The generally...

Seepage Control at Cochiti Dam, New Mexico
Significant design data, design assumptions and computations, and performance of the seepage control features provided at Cochiti Dam are summarized in this paper. The dam is a rolled...

Hydraulic Fracturing in Embankment Dams
There is now sufficient evidence to conclude that concentrated leaks occur commonly through the impervious sections of embankment dams by hydraulic fracturing without being observed, even...

Designing and Monitoring for Seepage at Calamus Dam
Given the complex, pervious nature of the foundation for Calamus Dam, every effort has been made to incorporate design features that will reduce and control the anticipated large volumes...

A Case History of Leakage from a Surface Impoundment
A manufacturing company constructed a 48-acre (19 hectare), unlined surface impoundment at a site in northern Texas to store wastewater. The site is underlain by unsaturated, alluvial...

Fracture Mechanics Analysis of Massive Hydraulic Fracturing Containment
The hydraulic fracturing containment problem is the subject of the present investigation. Unlike previous studies, the interface crack geometry with the correct crack tip singularity was...

Vehicle Sound Power measurement Using the Acoustic Intensity Method
The use of the two microphone Acoustic Intensity Method of obtaining accurate measurement of over-all sound power of large wheel loaders is described. This system is in operation, within...

Strength of Composite Beams under Seismic Loading
Effective width of a concrete slab of a composite beam is specified in various specifications, but their theoretical backgrounds are obscure. Originally, they must have been specified...

Load-Carrying Capacity and Remaining Life of First-Built Composite Girder Bridge in Japan
Kanzaki Bridge, Osaka, Japan, was the first steel-concrete composite bridge built in 1953 to carry the Osaka Prefectural Road over Kanzaki River. The bridge was removed in 1978 after 25...

Dynamic-Fatigue Response of Continuous Composite Bridges
The dynamic response of continuous composite bridges and the influence of fatigue loading at resonance frequency on the structural response are investigated. It is shown that cracking...

The Eurocodes and Shrinkage in Composite Beams
The two parts of this paper relate to different aspects of design procedures for composite structures of steel and concrete. First, recent developments in the coordination of the eight...

Strength of Biaxially Loaded SRC Columns
The paper presents the results of an experimental study on the elasto-plastic behavior of 'Steel reinforced concrete (SRC)' columns subjected to biaxially eccentric...

Beam-to-Column Connection of a Composite Structure
Composite structures can exhibit excellent performance against seismic force, and fire safety as well. However, the traditional steel reinforced concrete (SRC) system or concrete encased...

Beam to Column Stress Transfer in Composite Structures
To clarify the mechanism of the stress transfer from the steel beam to the composite column through the beam-column joint, eight exterior beam column assemblies were tested under reversed...

Seismic Strengthening of Existing RC Buildings
Seismic strengthening of existing reinforced concrete (RC) frame buildings by the use of steel braces or panels was studied experimentally. A special joint between steel elements and the...

Timber Bridge Decks
The portion of the nation's 500,000 bridge decks that are made of timber has been declining for years, as the old timber ones on secondary road bridges are rebuilt, in most...

Critical Load Program
The elastic critical load of a structural frame is a fundamental parameter in assessing its stability. It is an upper bound to the failure load of the frame, in the same way that the Euler...

Computers in a Planning Context: Another Reality
Over the past twenty years water resources planning has seen a great increase in the development of computer methods of analysis. This has transformed the way the hydrology, hydraulics,...

Personal Computers and Stormwater Management Programs
Urban flooding and drainage problems are the result of complex interactions between natural and man-made systems. Comprehensive analysis of the hydrologic characteristics of these problems...

A Case Study - Toms River Water Company, Toms River, New Jersey
Toms River Water Company provides water service to Dover Township, the Borough of South Toms River and portions of Berkeley Township, all in Ocean County, New Jersey. Existing supply facilities...

 

 

 

 