Seismic Safety Regulation of Existing Structures
Establishment of standards for seismic strengthening of existing buildings has been difficult since full compliance with current codes is generally too expensive. A general consensus has...
Historic Background of Seismic Construction in San Francisco
A seismic design and construction tradition has developed in California because of the unique experience with local earthquakes. After the 1906 earthquake and fire, building performance...
Equating Dynamic Analysis to Static Code Provisions
Building codes generally prescribe seismic design provisions that include a static lateral force procedure that can easily be combined with the gravity loads to design the structural elements....
Development of Inelastic Reduction Factors to Provide an Elastic Design Procedure
R factor values can only be rationally selected when they are based on in part nonlinear inelastic dynamic analyses of building system types. However, it is informative to discuss the...
1988 SEAOC and UBC Seismic Provisions
This paper highlights the major improvements to seismic design provisions incorporated in the 1988 Structural Engineers Association of California (SEAOC) 'Blue Book'...
Recent Developments in Isolation Hardware
Most isolation systems have at least two physical components: one specifically intended to add flexibility and the other to control the resulting deflections. However, other elements may...
Cracking the Fire Code
Local building codes specify fire resistance for members in buildings and other structures, and structural engineers select materials and assemblies that have passed a standard fire resistance...
The Church on Stilts
Christ Church Cathedral is an Anglican church situated in the heart of downtown Montreal. Constructed in 1859, it is a perfect example of English neogothic architecture, characterized...
Tension Leg Platform
a State of the Art Review
Prepared by the Task Group on Compliant Offshore Platforms of ASCE. This report considers the analysis and design of tension leg platforms (TLPs),...
Collapsible Soils in the Antelope Valley�California
Soils subject to hydroconsolidation, commonly referred to as collapsible soils, have a potential to undergo significant volume reductions upon wetting, with or without additional loading...
Foundations on Expansive Soils in Northern Virginia
Thick layers of clayey silts (MH) were observed at several sites where townhouse developments were planned. These deposits had a high shrink swell potential. Maximum swell pressure tests...
Fracturing of Rock Using Expansive Soundless Chemical Demolition Agents
The theoretical principles of the action of expansive soundless chemical demolition agents are presented. The procedure for using these demolition agents are briefly outlined. Differences...
Ground Failure Damage to Buildings During Earthquakes
Several case histories are examined to evaluate building damage as a function of the foundation type and type and amount of ground displacement. Extensional or vertical ground displacements...
Bearing Pressure?SPT Correlations for Expanded Base Piles in Sand
Design of enlarged base piles is usually carried out using correlations between SPT N values and point resistance. The results of full scale load tests are used to show that base resistance...
Performance of a Large Ribbed Mat on Cohesive Soil
The performance of a 678-ft by 304-ft (207-m by 93-m) ribbed concrete mat was studied to provide improved soil input parameters for design. The mat was constructed on a low plasticity...
Bearing Capacity of Shallow Foundation on Granular Column in Weak Clay
Laboratory model tests results for the ultimate bearing capacity of shallow rectangular foundations supported by granular columns made in weak clay have been presented. In all cases, the...
Performance of a Building Foundation Designed to Accommodate Large Settlements
The Eastern Airlines shuttle terminal at LaGuardia Airport in New York City is supported on spread footings founded in an incinerated refuse fill which overlies a deep deposit of slightly...
A New Combined Footing and Drilled Shaft Foundation Design
A conventional belled caisson foundation installation in glacial till to support a suburban Chicago 10-story office building was stopped when test caissons revealed excessive water-bearing...
Chemically Induced Foundation Heave
The Kerr-McGee Electrolysis Plant in Henderson, Nevada has had recorded upward movements of portions of the building in excess of 18 inches. Contours of the measured heave indicate that...
Ponds and Lagoons of Gulf Islands National Seashore
A physical and natural resource survey was conducted of the ponds and lagoons on Horn and Petit Bois Islands, Gulf Islands National Seashore, Mississippi. Petit Bois Island contains 17...