Yucca Mountain Site Characterization Project Performance Based Q List
In mid-1992, the Yucca Mountain Site Characterization Project (YMP) initiated a performance based 'Q' List development effort. This effort is intended to evolve a 'Q' List based upon the...
Application of Quality Assurance to Site Characterization
Siting studies for nuclear power plants are conducted for the purpose of determining the suitability of the site (a natural system) on plant systems that prevent the release of radioactive...
Safeguards Issues of Radioactive Wastes at DOE Sites
Radioactive waste management is not regarded as a safeguard-sensitive step in the nuclear fuel cycle. However, the accumulation of large amounts of fissile materials in wastes over a period...
Detachment Faults?Regulatory Implications for the Yucca Mountain Site
Site characterization investigations at the Yucca Mountain site, Nye County, Nevada consist of a combination of scientific data collection and analyses, and compliance with regulatory...
Seismic Reflection Profiling: Essential Geophysical Data for Yucca Mountain, Nevada
Yucca Mountain, Nevada, consists of a thick sequence of ashflow tuffs and lavas fractured into intact blocks with east-dipping strata, marginal broken zones characterized by dense faulting...
Large-Scale in Situ Heater Tests for Hydrothermal Characterization at Yucca Mountain
To safely and permanently store high-level nuclear waste, the potential Yucca Mountain repository site must mitigate the release and transport of radionuclides for tens of thousands of...
Core and Reaming Bit Studies in Yucca Mountain Tuffs
The Site Characterization Project is a major part of the work in determining the suitability of Yucca Mountain as a potential high level waste repository. Over 100 exploratory drill holes...
Fear of Permanence: The Challenge of Siting Interim Facilities
This paper examines an increasingly urgent and surprisingly difficult task: siting potentially hazardous facilities that are intended to operate for a limited period, such as a Monitored...
Calcite Deposits in Fractures at Yucca Mountain, Nevada
Calcite is one of the latest-formed minerals within fractures at Yucca Mountain. Petrographic and chemical studies of these calcites have the potential, in conjunction with fluid-inclusion...
Lead Isotopic Composition of Paleozoic and Late Proterozoic Marine Carbonate Rocks in the Vicinity of Yucca Mountain, Nevada
Paleozoic and Late Proterozoic marine carbonate rocks (limestones, dolomites, and their metamorphic equivalents) cropping out in the vicinity of Yucca Mountain contain lead with an isotopic...
Application of the Global Positioning System to Locating Remote Sites
The location of Near Field (NF) sampling stations, used for the radiological monitoring program portion of the site characterization phase of the Yucca Mountain Project, were determined...
Ambient Air Monitoring to Support HLW Repository Site Characterization
This paper is a description of the program that has been operating in support of the Yucca Mountain site site characterization activities since 1985.The ambient air monitoring is designed...
HWVP Compliance with the Hanford Site Solid Waste Acceptance Criteria
This report describes the Hanford Waste Vitrification project (HWVP), which will be located at the Haford Site. The Hanford Site encompasses a 560-mi2...
Yucca Mountain Site Characterization Project Exploratory Studies Facilities Construction Status
This paper discusses the progress to date on the construction planning and development of the Yucca Mountain Site Characterization Project (YMP) Exploratory Studies Facilities (ESF). The...
Functional Analysis: The Path to Effective Training
The regulatory requirements under which the Yucca Mountain Site Characterization Project (YMP) operates mandate that worker proficiency be achieved and maintained. Individuals performing...
GIS Reconstruction of Exposure to Water Supply Contaminants
Groundwater pollution resulting from improper waste handling practices in the aerospace industry contaminated the water supply in Tucson, Arizona. State and federal health officials concluded...
Groundwater Contaminant Transport at a Hazardous Waste Disposal Site, Pullman, Washington
Groundwater contamination at a hazardous waste site near Pullman, Washington is simulated by a numerical model. The aquifer at the site is classified as an unconfined valley aquifer. Solute...
The West Point Story?Chapter 5: Construction
As design of the West Point plant neared completion, the municipality of Seattle addressed construction of the facilities. The challenge was to build a complex wastewater treatment plant...
A Structural Analysis System
In this paper, the importance of the structural analysis in accordance with the construction progress was emphasized to accurately predict the structural behavior of prestressed concrete...
Information Integrated Construction (IIC)
The term 'INFORMATION INTEGRATED CONSTRUCTION (IIC)' was coined to describe the integration of construction information and practice through computer technology. We define information...
Return to search