Investigation of the Long-Term Creep Modulus for Buried Polyethylene Pipes Subjected to Constant Deflection
The tests reported in this paper are simulating the stress relaxation in constantly deflected pipe rings of various high density and medium density polyethylene grades. The pipe rings...
Long Term Deflection of Buried Plastic Sewer Pipes
During the 70's and the early 80's a research program has been carried out in Sweden regarding the long term behaviour of buried plastic pipes. The program has...
The Relative Strain as a Design Criterion for Buried uPVC Gravity Sewer Pipes
When designing buried plastic sewer pipes, the relative strain caused by deflection of the circular pipe section is of particular interest. The reason for increased interest is the present...
Dynamics of Buried Pipelines
Forced motion of pipelines due to stationary or moving loads is studied. The pipe is modeled as an elastic shell in an elastic (or viscoelastic) medium. The interaction of the shell and...
Experimental and Field Observation of Dynamic Behavior of Buried Pipelines
Cyclic torsion, axial pull-out, and bending data from experiments conducted on jointed utility pipelines buried at several depths are presented. It is found that linear relationships exist...
Numerical Simulation of Soil-Pipeline Interaction in a Ground Subsidence Zone
In this paper, the flexural interaction between a buried pipeline and the surrounding soil is examined by employing a combined boundary element-finite element scheme. The flexural interaction...
Earth Pressure and Surface Load Effects on Buried Pipelines
Rational techniques for analyzing earth pressure and surface load effects, based on finite element analysis methods, have been developed and applied extensively to the design of buried...
Dynamic Responses of Buried Pipelines
The dynamic responses of the pipelines are analyzed by the continuous mass matrix method by considering the soil as a bounded plane in which the pipeline is placed. The friction between...
Buried Fiberglass Pipe Response to Field Installation Methods
In 1970 near Yuma, Arizona, a field test installation of 30 inch diameter fiberglass pipe was constructed. Twelve years later the pipeline was remeasured. Measurements of pipe profile,...
Strains Induced by Combined Loading in Buried Pressurized Fiberglass Pipe
In 1983 Owens Corning Fiberglas and Utah State University collaborated on a study of combined strain behavior of fiberglass pipe to quantify the bending strain reduction as a function...
Long Term Testing of Centrifugally Cast Glass Fibre Reinforced Plastic Pipes (RIRP)
The paper discusses testing of pipe manufactured by centrifugal molding. The tests included external load tests, internal load, hydrostatic internal pressure, and cyclic internal pressure....
Buried Fiberglass Pipe Performance and Installation Requirements and Design Calculations in International Standardization
This paper elaborates on a proposed standard covering details of fiberglass pipe buried installation requirements and criteria for selection of pipe stiffness. It also discusses the selection...
Characterization of Soil Arching Above Buried Conduits
Conventional ways of assessing the effects of soil arching over buried conduits were examined by means of finite element analyses. It was found that neither of the conventional soil arching...
Longitudinal Stresses in Buried Pipes
Longitudinal stresses are inevitable in buried pipes even in pipes with gasketed joints. Longitudinal stresses in any pipe section are cumulative. They include stresses due to soil friction...
Stress and Strain Responses of a Soil-Pipe System to Vehicular Traffic
A 16-in. natural gas pipeline near Racine, Wisconsin, had been in service for some 30 years. In 1982 road widening operations on a line parallel with the pipe presented the opportunity...
Durability of Clay Pipe
Clay pipe, manufactured in accordance with ASTM C-700, has unusual resistance to attack by chemical agents. The pipe is highly stable in hydrochloric and sulfuric acid and subject to corrosive...
KEMCOR?A Chemical and Corrosion Resistant Piping System
KEMCOR is a new underground composite pipe system designed for chemical process use in such industries which require a high degree of corrosion resistance to varying concentrations and...
Inspection/Condition Analyses of Large Underground Pipelines
Inspection/Condition Analyses of Underground Pipelines (sewers and conduits) will be a necessary function of the pipeline Owner/Operator. The Condition Analyses and Inspection phases are...
Field Testing of 84-Inch-Diameter Plastic Pipe
During the summer of 1981, a research project was initiated to monitor strains and deformation in 84-inch diameter RPM (reinforced plastic mortar) pressure pipe. Three 20-foot (6. 1-m)...
Response of Buried Flexible Plastic Conduits Under Loading
Structural performance of 75 mm and 100 mm diameter plastic conduits embedded in Lloyd clay were examined experimentally in a laboratory soil bin, and numerically by the finite element...