Vibration Tests of Reservoir Structures Outlet Tower and Footbridge
This paper presents a field test procedure used in determining the dynamic properties of an outlet tower and footbridge for a major reservoir. Such factors as virtual water mass, soil-structure...

Dynamic Tests of LNG Storage Tanks for Earthquake Analysis of Liquid-Tank-Pile-Soil Interaction
This paper presents a field test procedure for determining the dynamic properties of large liquid natural gas (LNG) storage tanks under operating conditions. Two methods of vibratory excitation...

Refinements in Pseudo-Dynamic Test Procedures
One of the major concerns in seismic testing is whether the loading conditions imposed on a structure adequately represent those that might occur during a major earthquake. Response simulation...

Use of Vibration Tests to Determine Lateral Load Paths in Medium Rise Buildings
A structural system identification procedure is described in which an initial analytical model of a building is modified until it predicts accurately the mode shapes and natural frequencies...

Seismic Behavior of Long-Span Cable-Stayed Bridges
Special features of the earthquake-response analysis of cable-stayed bridges, subjected to multiple-support excitation, are presented including a basis for calculation of seismic forces...

Seismic Response Analysis of Two Major Bridge Structures
The seismic response analyses of two major bridge structures have been conducted. In these two bridges, portions of the piles are either submerged in the water or free-standing within...

Behaviour of Full-Scale Reinforced Concrete Structure on Realistic Foundation
A full-scale seven-story reinforced concrete building, tested as a part of U. S. -Japan Cooperative Research Program, performed well even under a severe earthquake loading condition. Nonlinear...

Seismic Behavior of a Full-Scale K-Braced Steel Frame?Part I Gross Behavior
As a part of the U. S. -Japan Cooperative Research Program Utilizing Large-Scale Testing Facilities, a six-story, 2 by 2 bay, concentrically K-braced steel building was constructed in...

Seismic Behavior of a Full-Scale K-Braced Steel Frame?Part II Local Behavior
The full-scale six-story concentrically K-braced steel building was subjected to Miyagi-Ken-Oki simulated earthquake whose peak intensity was 500gal. Local behavior of the test building...

Building Identification: Needs and Means
The need to conduct 'system identification' of existing buildings by nondestructive testing is discussed. A recommended flow-chart is exemplified. Existing dynamic...

Slab Participation in Frames under Lateral Loads
A unique opportunity to study slab participation was afforded by the U. S. -Japan Cooperative project on large scale testing. The data obtained from the full-scale 7-story building tested...

Earthquake Response Simulation Capacity of Pseudo Dynamic Testing?Experimntal Demonstration and Analytic Evaluation
The response accuracy of the pseudo dynamic test was evaluated from the shake table and pseudo dynamic tests conducted for a two story steel braced frame model. The obtained responses...

Evaluation of Seismic Strengthening of an Existing Building Using Base Isolation
This paper summarizes a study performed by Englekirk and Hart, Inc. to evaluate the feasibility of using base isolation to seismically upgrade an existing highrise building. To realize...

Earthquake Response of Five Story Reinforced Concrete Masonry Test Building
In 1986, a full-scale five story reinforced masonry test building is to be constructed in the Japan Building Research Institute Large-Scale Structure Test Laboratory, and through 1987...

Flexural Behavior of Reinforced Masonry Walls and Beams
Many reinforced masonry walls and beams were tested as a part of the U. S. -Japan cooperative research program on masonry building structures. Six concrete block and two clay brick masonry...

Stress-Strain Behavior of Grouted Hollow Unit Masonry
Experimental results from axial stress-strain tests including post-peak response on hollow unit masonry prisms are compared to those of previous researchers....

Full Scale Tests of Cladding Components
A full scale, six story, steel frame at the Building Research Institute, Tsukuba, Japan was constructed for a series of projects in the U. S. -Japan Cooperative Research Program. This...

Adaptation of Modal Testing Procedure to Shaker Tables
This article presents a technique for adapting current modal testing procedures to shaker table tests commonly used for qualification tests of nuclear and space related equipment. It involves...

Problems of Spectral Analysis in Dispersion Tests
The use of dispersive surface waves and spectral analysis methods is new to the nondestructive testing of airfield pavements. Such tests are to determine whether mechanical properties...

Comparative Seismic Response of Damped Braced Frames
The behaviours of braced steel building frames with friction joints and with eccentric bracing, under seismic forces, are compared. Nonlinear time history dynamic analysis is used. Friction...

 

 

 

 

Return to search