The Use of Cone Penetrometer Testing to Investigate Sand Fill Subsidence Beneath Highways
During construction of Interstate I-10 between Baton Rouge and LaPlace, Louisiana, highly organic swamp deposits were excavated and replaced with hydraulically pumped river sand. The main...
Effctive Stress Interpretation of In-situ Tests
Significant differences in terms of load-settlement curves obtained from Plate Load Tests (PLT) and q//c profiles obtained from Static Cone Penetration Tests (SCPT) at two sites with different...
Fast, Economical, Cone Testing of River Sediments
The objective of the study reported was to obtain quantitative geotechnical information over many square miles of Hudson River bottom. A hand held cone penetrometer was selected for use....
In Situ P and S Wave Velocity Measurement
A review of the in situ techniques to measure P and S wave velocities by seismic wave propagation is presented. A relatively new technique, the suspension PS logging method, is described...
In Situ Tests for Foundation Vibrations
There are several well established methods of determining shear modulus in situ and these are summarized in this paper. New techniques are being developed for in situ determination of...
N-Values Used to Predict Settlements of Piles in Egypt
A method is proposed for using the standard penetration N-values to predict the load-settlement curves for different piles used in Egyptian soils. The method is based on H. G. Poulos-E....
Initial Results From an In-Situ Consolidometer
An In-Situ Consolidation Evaluation Device (ICED) was developed for field measurement of consolidation parameters by electro-osmosis. A brief description of the test apparatus and the...
Comparison Between In-Situ Test Results
Penetration tests provide a means of obtaining data from which estimations can be made of the bearing capacity, settlement and liquefaction potential of the soils tested. Empirical formulae...
North American Standard Penetration Test Practice: An Essay
The Standard Penetration Test (SPT) is the in situ mechanical soil test most used by North American geotechnical practitioners. The equipment and procedures of the test have periodically...
Use of Piezometer Cone Data
The piezometer cone is generally regarded as the most efficient tool for stratigraphic logging of soft soils. A thin pore pressure element (5 mm thick) can sense layers a few centimeters...
CPT Indexing of In Situ OCR in Clays
Cone penetration tests may be used to index the in situ preconsolidation pressure in clay deposits. A specified relationship between C//u/ sigma //vo and the overconsolidation ratio (OCR)...
Lateral Stress Measurement During Cone Penetration
A lateral stress sensing cone penetrometer (LSSCP) was designed and fabricated. Based on the results of calibration chamber tests in sand, relationships between measured lateral stress,...
The Pressuremeter for Foundations: French Experience
The paper presents historical information on the development of the pressuremeter and its application in the Laboratories Central des Ponts el Chaussees (LCPC). The continuous research...
Dilatometer to Compute Foundation Settlement
Sixteen examples demonstrate how the S. Marchetti dilatometer test (DMT) provides soil compressibility data for the rapid calculation of foundation settlements with an average ratio of...
In Situ Tests on a Florida Peat
A geotechnical exploration program at a site predominated by surface peats has been performed. The study encompasses the performance of in situ field tests and laboratory soil tests. Field...
Field Study of Specialized Bacteria for Nitrification
A full scale field study using specialized bacteria was conducted to determine its effectiveness in achieving nitrification while quantifying dosage rates. A side-by-side comparison of...
Aerated Static Pile Composting of Wastewater Sludge: A Field Study in Longmont, Colorado
This is a report of experimental work at the Longmont wastewater plant at Colorado, on aerated static pile composting of wastewater sludge. 61% of the sludge mass used in compost piles...
Development of Data Quality Indicators for Indoor Air Pollution Measurements
Indoor air quality measurements pose a unique problem for the application of traditional Quality Assurance/Quality Control approaches. The lack of reference methods and materials in some...
Clay Liner Hydraulic Conductivity: Comparison of Field & Laboratory Tests
Clay liner hydraulic conductivities at three hazardous waste landfill cells in Oklahoma and Utah were measured in the laboratory and in the field during construction. Prior to construction...
An Evaluation of Sediment Resuspension Parameterizations
The recent attention to managing surface water toxic substances has resulted in a number of modeling approaches, all of which to a great or lesser extent require accurate treatment of...
Return to search