Performance of Water and Sewer Lifelines in the May 2, 1983 Coalinga, California Earthquake
Water supply and filtration systems for the City of Coalinga suffered little damage. The water transmission system suffered five breaks. The urban distribution system was disrupted, but...
Intermountain Power Project Seismic Design
Coal-fueled generation units of the Intermountain Power Project are constructed in a seismically active area of Utah (UBC Zone 3). The seismic design criteria were published during the...
An Overview of Earthquake Design Requirements at Pacific Bell
Seismic design considerations for the telephone system including outside plant and telephone equipment are discussed with emphasis placed on the requirements incorporated in the design...
Seismic Risk and Reliability of Telecommunications Systems
A general method for seismic risk analysis of telecommunications sytems evaluates by statistical means the earthquake environment and the earthquake vulnerability and effects on the system...
Update on Impact Effects in Nuclear Plants Part I?Overview and Need for Integrated Approach
In this paper, an ASCE working group on impact effects in nuclear plants updates the review of this technology contained in a five-year-old ASCE report. In Part I, an overview is given...
Update on Impact Effects in Nuclear Plants Part III?Review of Heavy Object Drop
The consequences of an accidental drop of a heavy component from a lifting device in a nuclear power plant are required to be evaluated even though the device may have been designed using...
Behavior of an Operating Floor Subjected to Heavy Load Drops
A structural evaluation of the behavior of a Boiling Water Reactor operating floor subjected to postulated heavy load impact is presented relative to the evaluation of nuclear industry...
Computer-Aided Load Monitoring System for Nuclear Power Plant Steel Framing Structures
The design of nuclear power plant steel framing structures is a long and involved process. It is often complicated by numerous changes in design loads as a result of additions, deletions...
Reliability Assessment of Indian Point Unit 3 Containment Structure Under Combined Loads
In the current design criteria, the load combinations specified for design of concrete containment structures are in the deterministic format. However, by applying the probability-based...
A Study of the Correlation of the Components of Instructure Motions During Earthquakes
Thirty-two buildings are selected that have all three components of motion recorded in the basement, midheight and top of the structure. The correlation coefficients of these motions,...
Tension Tests of Containment Wall Isolated Liner Plates
Two tests were conducted using an approximate 2:1 ratio of hoop to meridional load. This simple load ratio is a gross approximation of the liner plate loading in a containment subjected...
Preliminary Analysis of Large Penetration Enclosures for Containment Vessels Subject to Beyond Design Basis Loadings
Numerical simulations of the macro-deformations of the sealing surfaces (gasketed junctures) of a PWR steel containment vessel's equipment hatch subjected to accident loadings...
Modeling Techniques for Seismic Analysis of Supported Systems
An automated seismic qualification process is presented which integrates the modeling and evaluation aspects of supported system design. Emphasis is placed on baseplate and joint design....
A Pseudo Response Spectrum Method for Mark I Loads
A pseudo base motion response spectrum method is developed to uniquely evaluate the periodic condensation oscillation and chugging drag loads that may occur on submerged structures within...
Development of Concrete Nuclear Containment (ACI 359) Code Requirements as they Relate to Probability Based Load
The historical development of the load combinations used in concrete containment is presented in the paper. These load combinations are examined and identified in the light of the reasonable,...
Containment Integrity of SEP Plants under Combined Loads
The containment designs analyzed consisted of three inverted light-bulb shaped drywells used in boiling water reactor (BWR) systems, and three steel-lines concrete containments and a spherical...
Bayesian Procedure for Evaluation of Containment Capability
The functional requirements of a steel or concrete containment is to maintain the structural integrity as well as the leak-tight integrity of its pressure boundary under specified design...
Structural Performance Predictions for Liner Plates on Nuclear Facilities
The history of the use of liner plates is presented. It is shown that the liner plate can be buckled, and can be bonded or not bonded to the concrete. The buckled plate usually has bending...
Sodium Concrete Reaction ? Structural Considerations
An overview of the sodium concrete reaction phenomenon, with emphasis on structural considerations, is presented. Available test results for limestone, basalt, and magnetite concrete with...
Santa Clara Valley Weather Modification Program
This report describes a significant advancement in the Santa Clara Valley Water District's knowledge and understanding of its weather modification (cloudseeding) program,...
Return to search