Nonlinear Response of SDOF Systems to Intraplate Earthquakes
It is well established that there are characteristics differences between intraplate and interplate earthquakes. A parametric study of SDOF systems indicates that there is also consistent...

Connectors for Earthquake Resistant Structures
Damage assessments from the past several earthquakes located on the northern, central and southern zones of the San Andreas Fault - Cape Mendocino: April 1992, 7.1; Loma Prieta: October...

The European Approach to Seismic Design of Engineered Timber Constructions: The Case of Low-Dissipative Structures
In the present paper the importance of the dissipated energy on the actual structural behaviour of low-dissipative structures as glulam portal frames with mechanical fasteners under seismic...

A California Tower: Response to Seismic Forces
First Interstate World Center is a signature building for the city of Los Angeles. The granite clad tower with its serrated facade rises 1,018 ft. above street level. It is the tallest...

Seismic Behavior of High Strength Concrete Columns
Information on the ductility of high strength columns in seismic areas has been scarce. The available information is based mainly on small test columns subjected to monotonic concentric...

Long-Span Design for Seismic Forces?A Case Study of the Anaheim Arena
The design for the Anaheim Arena roof evolved in response to the strict requirements for a structure in a seismic zone 4 location. The support of the 329 ft. (100 m) by 444 ft. (135 m)...

Steel Plate Energy Absorbers for Improved Earthquake Resistance
This paper discusses results of an combined experimental and analytical investigation on seismic response of frame structures using welded steel triangular plates as added damping and...

Robust Control for Buildings Under Earthquake
Robust control techniques are applied to civil engineering structures subjected to earthquake excitation. Full state feedback and observer based control laws are used to reduce the response...

Earthquake Dampers Used for Seismic Retrofit of Building in San Francisco
For the first time ever in the United States, earthquake supplemental damping devices have been installed in a building in San Francisco. The devices used are Added Damping and Stiffness...

Passive Energy Dissipation Systems for Earthquake-Resistant Design
Passive energy dissipation devices, also known as supplemental damping devices, have been proposed as a means by which the earthquake resistance of a building can be substantially enhanced,...

Fluid Viscous Damper for Improving the Earthquake Resistance of Buildings
Experimental results are presented which demonstrate that the use of fluid dampers as add-on devices in moment resisting frames substantially increases damping and reduces seismic story...

Viscoelastic Dampers for Seismic Pounding Mitigation
A hysteretic model for viscoelastic (VE) damper is explained. The model accurately accounts for the effects of excitation frequency as well as temperature of the damper. Benefit of using...

Recent Developments in Seismic Isolation Technology
Large experimental research projects for isolators for both civil structures and nuclear reactor applications have been conducted at the Earthquake Engineering Research Center (EERC) over...

Evaluation of Seismic Isolation Schemes for a Historic Building
The U.S. Court of Appeals Ninth District building originally completed in 1905 with an expansion in 1933, suffered damage during the 1989 Loma Prieta earthquake. The building is currently...

Seismic Performance of Base-Isolated Building Structures
The theories and assumptions behind the base isolation technology are briefly described. As an illustration of its application, the base isolation of an existing 12-story hospital in Long...

Seismic Base Isolation Design for the San Bernardino County Medical Center Replacement Project
The SBCMC Replacement Project, located in Colton, California, consists of six separate building structures containing a total of approximately 86,000 m2...

Hybrid Control of Sliding Isolated Structures
The seismic response of buildings and bridges can be improved by isolating the structure with a seismic sliding bearings. Specialized passive devices are commonly used to complement these...

Diagnosing Lateral Strength of Existing Concrete or Masonry Buildings
A research prospectus is presented for improving present methods of structural evaluation for concrete and masonry buildings. Specifically, the proposed research plan is limited to strength...

Seismic Strengthening for Structures in Regions of Low Seismicity
Most existing structures were not designed to today's seismic codes and standards, and in fact in low seismicity regions codes did not require seismic design until recently....

Damage Estimation of Existing Bridge Structures
During recent earthquakes, severe damage have been reported in many bridge structures. Regardless of many damaged structures, methods to identify damage of structures are still limited...

 

 

 

 

Return to search