Designng to a Fault
Engineers designed a $30 million expansion of one of the Port of Los Angeles' busiest shipping terminals for a site sitting over the Palos Verdes Fault. Because closing the...
The Eccentric Entrance
Architects design irregularly shaped buildings to give their clients something different, and this creates problems for structural engineers, especially in earthquake zones. The Brinderson...
Massive Resistance
The recently completed structural reinforcement of the 95 year old landmark Salt Lake City & County building, and its 250 ft high central clocktower, is believed to be the first...
Caissons Skirt a Tunnel
Exchange Place Center is a 490 ft, 30 story office tower built directly over the existing transportation hub in Jersey City, N.J., where trains and buses meet the PATH Tubes that carry...
Minipiles Mature in America
After being born more than 40 years ago in Europe, minipiles are maturing in the United States. Their distinctive feature is a relatively small diameter, rarely larger than 12 in. Constructing...
Making Use of Contaminated Soils
Using hot-mix asphalt (HMA) is one answer to contaminated soil. HMA plants can be modified to accept some contaminated soil�a boon not only to the generator of the soil but the asphalt...
Seismic Cutoff
The John Hart Dam, which is a 40-year old dam in British Vancouver, Canada, has been rehabilitated to meet current seismic codes. BC Hydro, the utility that owns the dam, conducted a study...
Load and Resistance Factor Design for Engineered Wood Construction
A Pre-Standard Report
The information contained in this pre-standard report is intended to provide guidance to writers of a load and resistance factor design (LRFD) specification for engineered wood construction....
Swedish Approach to Infiltration and Percolation Design
Design of infiltration and percolation facilities is similar to detention facilities. The storage volume of an infiltration basin being the ponding volume on top of the infiltration surface...
AASHTO Design Concepts
The AASHO Road Test of 1958-60 grew out of a need to quantify the effects of increasingly heavier axle and gross loads and varying wheel load configurations on the performance of this...
Concrete Pavement Rehabilitation Research Findings
A study to improve the procedures for evaluating and rehabilitating concrete pavements was undertaken in 1985. Field and analytical studies have facilitated a new knowledge and understanding...
Natural Vibrations of Cables in a Flowing Fluid
Cable segments are important components in a wide variety of marine operations. Their nonlinearities are primarily geometric as characterized by large displacements and load-dependent...
Overview of Factors Involved in the Mexico Earthquakes
The Mexico earthquakes provided many opportunities for learning. New knowledge has been obtained and continuing research will provide additional knowledge. The earthquakes have also demonstrated...
Damage Statistics of the September 19, 1985 Earthquake
Grupo ICA has participated in all stages of the actions and analysis of the effects of this quake aimed at taking advantage of this disastrous experience and has prepared a complete study...
Analyses of Foundation Failures
During the earthquake of September 19th, 1985, many buildings tilted and underwent settlements, sometimes of very large magnitudes. This paper describes and analyzes these settlements....
Soil-Structure Interaction in Mexico City During the 1985 Earthquakes
The effects of the flexibility of the soil and the foundation on the seismic response of structures, by opposition to clear foundation failures, cannot be easily identified from a simple...
Seismic Design Criteria for Foundations on Control Piles
Control piles have been widely used in Mexico City for underpinning buildings with excessive settlements caused by the consolidation of the soft clay deposits, and as a foundation solution...
Performance Characteristics of Structures, 1985 Mexico City Earthquake
The 1985 Mexico City earthquake caused major damage to buildings, but not other structures, in the center of Mexico City, located approximately 400 km. from the epicenter. Due to soil...
R/C Frame Drift for 1985 Mexico Earthquake
This paper contains the results of a parametric study of the displacement response of multi-story reinforced concrete frames. Nonlinear lateral displacement responses were calculated for...
Evaluation of Performance of Concrete Buildings Damaged by the September 19, 1985 Mexico Earthquake
As a part of a general evaluation of the structural behavior of buildings during the 1985 earthquake in Mexico City, a detailed study of 8 damaged concrete buildings has been performed....