The Sand Dam
Currently under construction is the 443 ft. high sand fill dam. Being erodible, pervious and liquefiable, sand would normally be considered as n unsuitable material to construct LaVueltosa...
New Plant Treats River and Well Water
A new 16 mgd water softening plant at Elgin, Ill. is designed to treat raw water either from the Fox River or deep wells, or in any combination. Flexibility of the chemical feed systems...
Building Failures: Design Problems and Solutions
A Building Failures conference of the Engineering Foundation dissected the problems leading to failures and recommended ways to reduce failures. This article discusses value engineering,...
Engineering Liabilities for Design of a Bridge That Failed During the San Fernando Earthquake
On February 9, 1971, the San Fernando Valley in Southern California experienced a major earthquake. Among the victims were two men who were killed when a bridge connector ramp of a newly...
Seismic Considerations for the Century Freeway
The Century freeway (Interstate 105), will be an 18 mile (29 km) long, six-lane facility with 2 central transit/HOV lanes, located in Los Angeles, California. The freeway alignment crosses...
Seismic Design for Sacramento Light Rail Transit System
The Sacramento Light Rail Transit Project is an 18. 5 mile system which provides the trunk line service for an integrated Bus/LRT public transportation system. Seismic design utilized...
Seismic Design of Underground Structures Southern California Metro Rail Project
The effect of earthquakes on underground structures is the imposition of an arbitrary deformation which cannot be changed by strengthening the structure. The structural design goal is...
Base Isolation Concepts for Seismic Bridge Retrofit
Failures in past earthquakes have indicated three major problem areas with existing bridges. The first is the vulnerability of existing rocker and roller type bearings and this is coupled...
Seismic Risk and Decision Analysis of Lifeline Systems
This paper provides general guidelines for performing lifeline seismic risk and decision analyses. Relevant input models are introduced as they support the performance of component and...
Retrofitting Lifeline Facilities: The Japanese Approach
A brief history of the prediction of a major earthquake in the Tokai Area of Japan is reviewed. Planning and mitigation incorporating all levels of government and the private sector is...
CSMIP Strong-Motion Instrumentation and Records from Transportation Structures?Bridges
Seven transportation structures have been instrumented by the California Strong Motion Instrumentation Program (CSMIP), including four bridges. Records (in excess of 0. 25 g maximum acceleration)...
Seismic Design of Airport Control Towers
The paper describes state-of-the-art design in seismically active areas. It includes a review of current code design parameters and specific tower design criteria. Tower design examples...
Port of Seattle Seismic Waterfront Design
This paper describes the soil seismic design process, using the design developed for a concrete apron project at Terminal 20 as an illustration. Damage by the 1965 earthquake is described....
Seismic Response of Port and Harbor Facilities
A research program compiled information regarding the behavior of port and harbor facilities during past earthquakes. The potential for significant damage to port and harbor facilities...
Performance of Water and Sewer Lifelines in the May 2, 1983 Coalinga, California Earthquake
Water supply and filtration systems for the City of Coalinga suffered little damage. The water transmission system suffered five breaks. The urban distribution system was disrupted, but...
Dynamic Response Correlation of Cylindrical Tanks
The May 1983 Coalinga Earthquake provided an opportunity to correlate earthquake performance of cylindrical liquid storage tanks with behavior observed in laboratory shaking table experiments....
Intermountain Power Project Seismic Design
Coal-fueled generation units of the Intermountain Power Project are constructed in a seismically active area of Utah (UBC Zone 3). The seismic design criteria were published during the...
An Overview of Earthquake Design Requirements at Pacific Bell
Seismic design considerations for the telephone system including outside plant and telephone equipment are discussed with emphasis placed on the requirements incorporated in the design...
Seismic Risk and Reliability of Telecommunications Systems
A general method for seismic risk analysis of telecommunications sytems evaluates by statistical means the earthquake environment and the earthquake vulnerability and effects on the system...
Dome
Roofed with the worlds largest diameter wood dome at 530 ft., the Tacoma Dome, a multi-purpose sports and convention center has helped revitalize a blighted part of that Washington state...
Return to search