Strains Induced by Combined Loading in Buried Pressurized Fiberglass Pipe
In 1983 Owens Corning Fiberglas and Utah State University collaborated on a study of combined strain behavior of fiberglass pipe to quantify the bending strain reduction as a function...

Long Term Testing of Centrifugally Cast Glass Fibre Reinforced Plastic Pipes (RIRP)
The paper discusses testing of pipe manufactured by centrifugal molding. The tests included external load tests, internal load, hydrostatic internal pressure, and cyclic internal pressure....

Buried Fiberglass Pipe Performance and Installation Requirements and Design Calculations in International Standardization
This paper elaborates on a proposed standard covering details of fiberglass pipe buried installation requirements and criteria for selection of pipe stiffness. It also discusses the selection...

Characterization of Soil Arching Above Buried Conduits
Conventional ways of assessing the effects of soil arching over buried conduits were examined by means of finite element analyses. It was found that neither of the conventional soil arching...

Longitudinal Stresses in Buried Pipes
Longitudinal stresses are inevitable in buried pipes even in pipes with gasketed joints. Longitudinal stresses in any pipe section are cumulative. They include stresses due to soil friction...

Stress and Strain Responses of a Soil-Pipe System to Vehicular Traffic
A 16-in. natural gas pipeline near Racine, Wisconsin, had been in service for some 30 years. In 1982 road widening operations on a line parallel with the pipe presented the opportunity...

KEMCOR?A Chemical and Corrosion Resistant Piping System
KEMCOR is a new underground composite pipe system designed for chemical process use in such industries which require a high degree of corrosion resistance to varying concentrations and...

Inspection/Condition Analyses of Large Underground Pipelines
Inspection/Condition Analyses of Underground Pipelines (sewers and conduits) will be a necessary function of the pipeline Owner/Operator. The Condition Analyses and Inspection phases are...

Response of Buried Flexible Plastic Conduits Under Loading
Structural performance of 75 mm and 100 mm diameter plastic conduits embedded in Lloyd clay were examined experimentally in a laboratory soil bin, and numerically by the finite element...

Large Diameter Plastic Pipe Design
This paper presents a rationale for the design of large diameter plastic pipes for gravity flow applications. This procedure, applicable for all plastic pipes, adapts state-of-the-art...

Design of Non-Pressure Very Flexible Plastic Pipe
There is considerable debate about the correct structural design procedure to be used for very flexible plastic pipe (VFP) - typically glass-fiber reinforced pipe (GRP), reinforced plastic...

Proportioning Reinforcement for Buried Concrete Pipe
The proportioning of reinforcement between inner and outer cages that is specified in ASTM Standard Specification C76 for concrete pipe in sewer and culvert applications is examined in...

Predicting Overland Flow and Infiltration
The kinematic overland flow and the Green-Ampt infiltration equations are coupled and rewritten in terms of several nondimensional parameters. Constant values of these parameters imply...

Aggregation and Consolidation of Phosphatic Clays
The consolidation behavior of aggregated phosphatic clays has been investigated using a bench scale centrifuge. It was determined that aggregation of the clays with phosphogypsum, a waste...

South Branch Rockaway Flood Water Study
The paper reports on a study to analyze in detail various methods of storm water management. The technical studies were carried out in an actual watershed setting to arrive at a recommended...

Entrainment of Interstitial Water by Overland Flow
The paper reports on a study to investigate the entrainment of interstitial soil water by overland flow. A diffusion model was developed to describe the subsurface concentration and the...

Turbidity Control Measures Associated with Reclamation of an Abandoned Phosphatic Waste Clay Pond
Area 3A in the Tenoroc State Reserve near Lakeland, Florida is an inactive and abandoned phosphatic waste clay area. The disposal area has been inactive for several years and the clays...

Advances in Selective Withdrawal
The authors present the results of recent selective withdrawal research in the form of a general mathematical description of this stratified flow phenomenon. A new description for boundary...

Ground-Water Drainage to Surface Mines Refined
Changes in seepage flux and hydraulic head (ground-water level) resulting from ground-water drainage into the first and subsequent cuts of a surface coal mine can be estimated by a technique...

A Numerical Model of Water Movement Through Clay Liners
Regulations controlling landfill design typically specify design details such as a minimum liner thickness, maximum permeability of required gradation curves for the clay liner material....

 

 

 

 