Highlights of the New ASCE Standards on Composite Deck Floor Slabs
This paper presents highlights of the newly approved and printed ASCE Standard on the design and construction of composite floor deck slabs utilizing cold-formed steel. In 1992 four documents...

European Good Practice in Composite Floor Construction
Previous European experience, research and design for composite slabs with profiled steel decking are discussed. Present efforts to harmonize composite slab design and good construction...

The Steel Deck Institute Method for Composite Slab Design
The Steel Deck Institute (SDI) of the USA has synthesized the composite slab research and testing that has been conducted in the U.S. during the past 25 years and has presented a design...

Effects of Creep in Cable-Stayed Composite Bridges
The paper summarizes the various ways in which creep in the concrete slab may affect the stresses in a cable-stayed composite bridge. It explains one effect in particular which is not...

Replacement Steel Bridges for Motorway Widening
Case studies are presented of new applications of composite construction which offer speedy construction of replacement bridges over existing motorways. Spans of 45 m clear the widened...

Strength and Stiffness Behavior of Composite Steel Grid Decks
This paper briefly discusses the historical development of composite steel grid decks. The static and fatigue behavior under bending of filled and unfilled steel grid decks (exodermic)...

Fatigue of a Steel Plate and Concrete Composite Bridge Deck by Moving Loads
This paper is devoted to reveal fatigue characteristics of a steel plate and concrete composite bridge deck, which is often called the Robinson slabs, subjected to vehicle loads. 16 model...

Influence on Steel Deck on Composite Beam Strength
Results of a recent study were described in which 7 push-out tests and 4 composite beam tests were conducted. The results were consistent with other recent studies reported in the literature,...

Composite Beams with Headed Studs in Narrow Ribbed Metal Deck
This paper presents the results of sixteen push-out tests conducted to study the behavior of headed stud connectors in composite beams with narrow ribbed metal deck placed parallel to...

Plastic Potential
Some 220,000 tons of epoxy-coated steel has been used in the construction of bridge decks since 1987, but some have raised questions about its long-term durability. New materials for prestressing...

Hassle-Free Bridge Rehab
Engineers involved in Cleveland's Main Bridge rehab invoked whatever was necessary to keep area traffic moving and the bridge closure period to a minimum. They helped change...

Design Cable-stayed Bridge for Cost Effectiveness and Safety
Innovative design approach is needed to enhance the prestigious status enjoyed by cable-stayed bridges. The present paper aims at such a goal of cost effectiveness and safety by providing...

Response of Suspension and Deck Arch Bridges to Spatially Varying Ground Motion
Recent awareness of the spatial variation of earthquake ground motion has caused concern about the safety of large engineered structures under seismic excitation. The effects of spatially...

Design and Construction of Waterfront Facilities at U.S. Navy Homeport at Ingleside, Texas
The waterfront facilities for the largest of the Navy's new homeports in the Gulf of Mexico were completed in 1990. The project included over 2,500 feet (762 m.) of deep draft bulkhead...

West Point Temporary Construction Dock
The West Point temporary construction dock is designed to provide construction access for the West Point treatment plant project located in Seattle, Washington. The dock plays a major...

Principles of Infrared Thermography and Application for Assessment of the Deterioration of the Bridge Deck at the Zoo Interchange
This paper details the principles of infrared thermography from the underlying theoretical considerations to the physical constraints involved with performing the test. Infrared (IR) thermography...

Bridge Deck Distress and Repairs
The primary cause of bridge deck deterioration are cyclic freeze-thaw exposures and reinforcing steel corrosion caused by the extensive use of de-icing salts. However, there are other...

Tests of Full-Size Pultruded FRP Grating Reinforced Concrete Bridge Decks
Results of tests of full-size concrete bridge deck slabs reinforced with commercially produced pultruded fiber-reinforced plastic (FRP) gratings are presented. The slabs were designed...

Splice/Development Length Requirements for FRP Grids Used in the Structural Reinforcement of Concrete
The research presented in this paper program was directed towards determining development length and splice requirements for FRP grids used in the reinforcement of concrete structures....

Overlays on Deck
By the summer of 1993, a standard specification may be on the books for polymer concrete bridge-deck overlays�a high-tech rehab technique requiring a combination of plastic binder�such...

 

 

 

 

Return to search