85 Stories in Kuala Lumpur?The 5th and 6th Tallest Buildings in the World
A concrete core and cylindrical concrete tube structure provides a safe, elegant, efficient and constructible solution to the challenge of designing the world's 5th and 6th tallest buildings,...

Seismic Behavior of High Strength Concrete Columns
Information on the ductility of high strength columns in seismic areas has been scarce. The available information is based mainly on small test columns subjected to monotonic concentric...

Seismic Vulnerability and Upgrading of Nonductile Reinforced Concrete Frames Using Passive Supplemental Dampers
The effects of vulnerable details of lightly reinforced concrete frames constructed prior to the 1970s is evaluated from tests conducted of two beam/slab/column subassemblages drawn from...

High-Strength Concrete Joints Under Cyclic Loading
This experimental investigation was undertaken to check the validity for high-strength concrete beam-column joints of recommendations made by ACI-ASCE (American Concrete Institute-American...

Orthotropic Rigidities of Curved Concrete Waffle Slabs
Analytical expressions are derived for predicting the flexural and torsional rigidities during the pre-cracking and post-cracking stages for horizontally- curved waffle slab structures....

Blast-Damaged Concrete Structures in Beirut
This paper describes the effect of blasting loads on structural members. It identifies predominant structural systems in war-damaged zones of Beirut and to explain typical damage mechanisms....

Steel Plate Energy Absorbers for Improved Earthquake Resistance
This paper discusses results of an combined experimental and analytical investigation on seismic response of frame structures using welded steel triangular plates as added damping and...

Earthquake Dampers Used for Seismic Retrofit of Building in San Francisco
For the first time ever in the United States, earthquake supplemental damping devices have been installed in a building in San Francisco. The devices used are Added Damping and Stiffness...

Fluid Viscous Damper for Improving the Earthquake Resistance of Buildings
Experimental results are presented which demonstrate that the use of fluid dampers as add-on devices in moment resisting frames substantially increases damping and reduces seismic story...

Seismic Base Isolation Design for the San Bernardino County Medical Center Replacement Project
The SBCMC Replacement Project, located in Colton, California, consists of six separate building structures containing a total of approximately 86,000 m2...

Neural Networks in Structural Control
Let the response of a simple two-story frame to a stochastic dynamic excitation be controlled by activating suitable actuators. A neural network is trained to recognize, from the measurement...

Diagnosing Lateral Strength of Existing Concrete or Masonry Buildings
A research prospectus is presented for improving present methods of structural evaluation for concrete and masonry buildings. Specifically, the proposed research plan is limited to strength...

Joint Design in Composite Columns/Steel Beam Structures
The use of a composite building system, utilizing a composite exterior column and a concrete spandrel beam system, proposed by Dr. Fazlur Khan in 1967, is recalled. In the last 25 years,...

Axial Capacity of Concrete Infilled Steel Box Column with Biaxial Bending
The objective of this study was to investigate the feasibility of using the Bresler reciprocal load method to calculate the axial capacity of a concrete infilled steel box column subjected...

Concrete Arch Bridges for Supporting Steel Conduits of Mingtan Pumped Storage Project
For the Mingtan Pumped Storage Project of an installed capacity of 1600 MW, two parallel waterways have been constructed for conveying flows between the upper reservoir and the lower reservoir...

Design of the Main Bridge of the Huachiang Bridge
The Huachiang Bridge will be reconstructed by erecting the deck structure in two steps to avoid reducing or interfering with the bridge's traffic flow. Both the analysis and the detailed...

Response of Concrete Filled Grid Decks Under Static Loads
This paper briefly discusses the bending strength and stiffness of concrete filled grid decks that are subjected to static loads. The influence of design parameters (traffic flow direction,...

Physical Testing of Two R/C Skewed Slab Bridges with Integral Wall Abutments
Two one-third scale models of an existing reinforced concrete skewed slab bridge with integral wall abutments were tested statically to failure. Typically, these bridges are designed using...

Linear and Nonlinear Finite Element Analyses of RC Skewed Slab Bridges with Integral Wall Abutments
The design of rigid-frame skewed slab bridges is complicated by higher shears and moments near the obtuse corner (see Fig.1). While the finite element method can be used to compute these...

Developing a New Construction Policy for Bridge Management
The SHRP Program and other rehabilitation strategies are based on extending the life of concrete bridge elements. In the Bridge Inventory are a number of bridges that must be reconstructed....

 

 

 

 

Return to search