Modeling Failure Probability of Underground Pipes
Factors influencing the performance of underground gas pipes are identified through a literature search and contacts with several utility companies. These factors are categorized as (i),...

Stress-Intensification Factor and Flexibility Factor in Seismic Analysis of Continuous Buried Pipelines
The topics of intensified stresses and increased flexibility in pipe bends subjected to bending loads are discussed in this paper. Also discussed are dynamic strain compatibility between...

A Practical Approach to Selection of Waterline Materials for Use in Expansive Soils
The authors previously investigated the performance of asbestos-cement, polyvinyl chloride and ductile iron pipe in the expansive soil environment. Expansive soil forces on the pipe were...

Bending Moment of Underground Flexible Pipes in a Centrifuge
The effect of several factors on bending moment of an underground flexible pipe section buried in a ditch with sheet piling was investigated experimentally by means of centrifugal model...

Field Burial Tests of Corrugated Double Wall PVC Pipe
A new lightweight PVC pipe, consisting of a smooth inner wall and a corrugated outer wall, has been introduced in the U. S. sanitary sewer market in 4 through 10 in. diameters. Field burial...

Long Term Deflection of Buried Plastic Sewer Pipes
During the 70's and the early 80's a research program has been carried out in Sweden regarding the long term behaviour of buried plastic pipes. The program has...

Dynamics of Buried Pipelines
Forced motion of pipelines due to stationary or moving loads is studied. The pipe is modeled as an elastic shell in an elastic (or viscoelastic) medium. The interaction of the shell and...

Determining the In-Place Density of Soils Using the Sleeve Method
The sleeve method of determining the in-place density was developed by Bureau of Reclamation field personnel for cohesionless, fine, gravel soils used for pipe bedding when other methods...

Numerical Simulation of Soil-Pipeline Interaction in a Ground Subsidence Zone
In this paper, the flexural interaction between a buried pipeline and the surrounding soil is examined by employing a combined boundary element-finite element scheme. The flexural interaction...

Earth Pressure and Surface Load Effects on Buried Pipelines
Rational techniques for analyzing earth pressure and surface load effects, based on finite element analysis methods, have been developed and applied extensively to the design of buried...

Dynamic Responses of Buried Pipelines
The dynamic responses of the pipelines are analyzed by the continuous mass matrix method by considering the soil as a bounded plane in which the pipeline is placed. The friction between...

Buried Fiberglass Pipe Response to Field Installation Methods
In 1970 near Yuma, Arizona, a field test installation of 30 inch diameter fiberglass pipe was constructed. Twelve years later the pipeline was remeasured. Measurements of pipe profile,...

Long Term Testing of Centrifugally Cast Glass Fibre Reinforced Plastic Pipes (RIRP)
The paper discusses testing of pipe manufactured by centrifugal molding. The tests included external load tests, internal load, hydrostatic internal pressure, and cyclic internal pressure....

Characterization of Soil Arching Above Buried Conduits
Conventional ways of assessing the effects of soil arching over buried conduits were examined by means of finite element analyses. It was found that neither of the conventional soil arching...

Longitudinal Stresses in Buried Pipes
Longitudinal stresses are inevitable in buried pipes even in pipes with gasketed joints. Longitudinal stresses in any pipe section are cumulative. They include stresses due to soil friction...

A Study of Inlet Control Alternatives for SWM
A laboratory study of alternatives for effecting inlet control on urban storm sewer systems for stormwater management (SWM) is described. The test facility was a full-size physical model...

Stress and Strain Responses of a Soil-Pipe System to Vehicular Traffic
A 16-in. natural gas pipeline near Racine, Wisconsin, had been in service for some 30 years. In 1982 road widening operations on a line parallel with the pipe presented the opportunity...

KEMCOR?A Chemical and Corrosion Resistant Piping System
KEMCOR is a new underground composite pipe system designed for chemical process use in such industries which require a high degree of corrosion resistance to varying concentrations and...

Field Testing of 84-Inch-Diameter Plastic Pipe
During the summer of 1981, a research project was initiated to monitor strains and deformation in 84-inch diameter RPM (reinforced plastic mortar) pressure pipe. Three 20-foot (6. 1-m)...

Response of Buried Flexible Plastic Conduits Under Loading
Structural performance of 75 mm and 100 mm diameter plastic conduits embedded in Lloyd clay were examined experimentally in a laboratory soil bin, and numerically by the finite element...

 

 

 

 