An Overview of Earthquake Design Requirements at Pacific Bell
Seismic design considerations for the telephone system including outside plant and telephone equipment are discussed with emphasis placed on the requirements incorporated in the design...

Dome
Roofed with the worlds largest diameter wood dome at 530 ft., the Tacoma Dome, a multi-purpose sports and convention center has helped revitalize a blighted part of that Washington state...

Ocean Energy
The Ocean Thermal Energy Conversion (OTEC) component nominated this year as an ASCE Outstanding Civil Engineering Achievement involves the most critical design problem; the cold water...

Energy Recovery
In Albany, N.Y. the state and city cooperated in designing and building a refuse-into-steam energy plant that has several unique features. In most such facilities, the entire plant is...

Low Velocity Impact Tests on Reinforced Concrete Panels
The results of low velocity impact tests on reinforced concrete panels are presented. These tests were conducted to investigate the behavior of reinforced concrete flexural elements subjected...

Coupled Vertical-Rocking Response of Base-Isolated Structures
A base-isolated building can have a small horizontal eccentricity between the center of mass of the superstructure and the center of rigidity of the supporting bearings. The structure...

Major Considerations in Scale Modeling of Reinforced Concrete Containment Structures
Reinforced concrete containment structures pose unique modeling problems, especially when leakage integrity is of interest. This paper presents a general discussion of modeling considerations...

Evaluation of the Ultimate Pressure Capacity of Rectangular HVAC Ducts for Nuclear Power Plants
Structural design criteria are presently based on the AISI Code which limits the duct panel width-to-thickness ratio to a maximum of 500 and the maximum height-to-thickness ratio to 200,...

Strength and Stiffness Characteristics of Steel Ladder-Type Cable Trays
Ladder-type cable trays identical with the as-built are generally tested to establish their strength and stiffness characteristics. Test data for systems in operating plants, however,...

Composite-System Approach for Seismic Analysis of Secondary Systems
An accurate and efficient method for seismic analysis of multiply supported, multi-degree-of-freedom secondary subsystems is developed. The method accurately accounts for the effects of...

Development of Concrete Nuclear Containment (ACI 359) Code Requirements as they Relate to Probability Based Load
The historical development of the load combinations used in concrete containment is presented in the paper. These load combinations are examined and identified in the light of the reasonable,...

Containment Capability
Section 2. 0 of this report contains a description of analysis methods for the containment structure. Testing on containment models and sections of containments is described. Section 3....

Sodium Concrete Reaction ? Structural Considerations
An overview of the sodium concrete reaction phenomenon, with emphasis on structural considerations, is presented. Available test results for limestone, basalt, and magnetite concrete with...

Slurry Pipeline Control Systems
The paper documents the La Perla-Hercules pipeline and its control system. This eight and fourteen-inch, 382-kilometer iron ore concentrate slurry pipeline was commissioned in June of...

Design and Performance of Buried Fiberglass Pipes ? A New Perspective
The buried performance of fiberglass pipes was the subject of a comprehensive and multifaceted research program carried out in 1982 and 1983. Instrumentation, capable of accurately tracing...

Performance of Low Stiffness Plastic Pipe in Stiff Soils
Large diameter pipe made from ductile plastics, such as polyvinyl chloride (PVC), polypropylene (PP) and high density polyethylene (HDPE) can be effectively utilized in subsurface installations...

The Present Status of Application of the Plastic Concepts in Structural Design
The different approaches of recognizing plastic behavior in the design of steel structures are reviewed and the design requirements that assure successful utilization of this behavior...

Probing the Past
In Denver, Colorado, 12 buildings of an old abandoned brewery complex were to be renovated into a 270,000 sq ft shopping, entertainment and restaurant complex. Rather than conduct a thorough...

Testing for Salt Damage
Salts used to melt snow can contribute to deterioration of concrete structures. Various tests were used to determine the extent of damage in two structures in Rochester, N.Y. One is an...

In-Plane Composite Drains
Drainage of water from outside basement walls, behind retaining walls, or highway cut or fill slopes, has long been a problem. A common solution is the aggregate drain. Often, installation...

 

 

 

 

Return to search