Sensitivity of Peak Dynamic Responses to Input Factors
Responses have been calculated for the Zion Unit 1 plant, using the SSMRP computer code SMACS, as part of the seismic probabilistic risk assessment performed by the Seismic Safety Margins...
Seismic Evaluation of Reinforced Masonry Walls
Masonry walls in operating nuclear plants are in many cases found to be overstressed in terms of allowable stresses when evaluated using current seismic design criteria. However, experimental...
Seismic Capacities of Masonry Walls at the Big Rock Point Nuclear Generating Plant
An evaluation to determine the ability of selected concrete block walls in the vicinity of essential equipment to withstand seismic excitation was conducted. The seismic input to the walls...
The Use of Joint Reinforcement in Qualifying Masonry Walls in Nuclear Power Plants
Wire joint reinforcement has been traditionally used in block masonry walls for crack control and to provide continuity for multiple wythe walls. In a number of nuclear power plants, vertically...
Probabilistic Seismic Analysis of a Nuclear Power Plant Steel Containment
Concern for the safety of nuclear power plants has motivated efforts to determine the statistical characteristics of the seismic resistance of steel containments under various types of...
New Developments in Seismic Analysis of Primary and Secondary Systems
This paper presents recent advances made at NCSU in the seismic analysis of these systems. Algorithms are presented by which coupled mode shapes and frequencies can be evaluated without...
State-of-the-Art of Development of Floor Spectra
Floor spectra are used as seismic inputs for the design and qualification of subsystems and equipment. Until very recently, the time history analyses with single acceleration time history...
A Study of the Correlation of the Components of Instructure Motions During Earthquakes
Thirty-two buildings are selected that have all three components of motion recorded in the basement, midheight and top of the structure. The correlation coefficients of these motions,...
Tension Tests of Containment Wall Isolated Liner Plates
Two tests were conducted using an approximate 2:1 ratio of hoop to meridional load. This simple load ratio is a gross approximation of the liner plate loading in a containment subjected...
Preliminary Analysis of Large Penetration Enclosures for Containment Vessels Subject to Beyond Design Basis Loadings
Numerical simulations of the macro-deformations of the sealing surfaces (gasketed junctures) of a PWR steel containment vessel's equipment hatch subjected to accident loadings...
Evaluation of the Ultimate Pressure Capacity of Rectangular HVAC Ducts for Nuclear Power Plants
Structural design criteria are presently based on the AISI Code which limits the duct panel width-to-thickness ratio to a maximum of 500 and the maximum height-to-thickness ratio to 200,...
Modeling Techniques for Seismic Analysis of Supported Systems
An automated seismic qualification process is presented which integrates the modeling and evaluation aspects of supported system design. Emphasis is placed on baseplate and joint design....
Analytical Solution of Cable Tray Hanger 3D Structural Interaction under Seismic Loading
Structural design of cable tray hangers is controlled by the Nuclear Regulatory Commission's stringent requirements of seismic analysis. A finite element space frame model...
Vibration Isolation of Cable Tray Hangers
Analytical and experimental investigations have been performed to partially evaluate the feasibility of using much more flexible support systems than those presently used to support electrical...
Piping Analysis: A Flexibility Approach
Design for the vertical and horizontal accelerations associated with a seismic event coupled with low allowable loads on equipment are two primary contributors to the current situation....
Composite-System Approach for Seismic Analysis of Secondary Systems
An accurate and efficient method for seismic analysis of multiply supported, multi-degree-of-freedom secondary subsystems is developed. The method accurately accounts for the effects of...
Fluid Structure Interaction Analysis of a Concrete Suppression Chamber of Mark I Containment System
Recent studies have demonstrated that the interaction between a structure and fluid can have a significant influence on the response of the overall system when subjected to certain dynamic...
A Pseudo Response Spectrum Method for Mark I Loads
A pseudo base motion response spectrum method is developed to uniquely evaluate the periodic condensation oscillation and chugging drag loads that may occur on submerged structures within...
Development of Concrete Nuclear Containment (ACI 359) Code Requirements as they Relate to Probability Based Load
The historical development of the load combinations used in concrete containment is presented in the paper. These load combinations are examined and identified in the light of the reasonable,...
Containment Integrity of SEP Plants under Combined Loads
The containment designs analyzed consisted of three inverted light-bulb shaped drywells used in boiling water reactor (BWR) systems, and three steel-lines concrete containments and a spherical...
Return to search