A Safe Skyscraper For the Seismic City
When completed in late 1989, the 73-story First International World Center will be the tallest office building in Los Angeles. The steel structure of the building was designed to be ductile...
Making Use of Contaminated Soils
Using hot-mix asphalt (HMA) is one answer to contaminated soil. HMA plants can be modified to accept some contaminated soil�a boon not only to the generator of the soil but the asphalt...
Seismic Cutoff
The John Hart Dam, which is a 40-year old dam in British Vancouver, Canada, has been rehabilitated to meet current seismic codes. BC Hydro, the utility that owns the dam, conducted a study...
AASHTO Design Concepts
The AASHO Road Test of 1958-60 grew out of a need to quantify the effects of increasingly heavier axle and gross loads and varying wheel load configurations on the performance of this...
Subsurface Injection of Storm Water Runoff into an Underground Storage of Bangkok
Subsurface injection through a well into sand and gravel formations of the Bangkok aquifer of untreated canal water whose composition considered similar to that of storm water runoff,...
Analysis of Hydraulic Impacts at the Tucson Reclaimed Water Recharge Project
The Tucson Reclaimed Water Recharge site has been implemented with increasingly sophisticated calculation methods as data collection efforts advanced. Initial project scoping utilized...
Artificial Recharge of Ground Water via Paddy Fields in an Alluvial Fan, Northern Japan
Artificial ground water recharge via paddy fields was tested during the winters of 1985/86 and 1986/87 in order to protect declining water levels. The purpose of this paper is to discuss...
Techniques of Artificial Recharge from an Ephemeral Wadi Channel Under Extreme Arid Conditions
A series of field experiments and theoretical analysis was carried out for the alluvial system in Wadi Tabalah in order to determine the feasibility of implementing artificial recharge...
Journal of Aerospace Engineering
The Journal of Aerospace Engineering promotes the implementation and development of space and aerospace technologies and their transfer to other civil engineering applications. Topics of interest include...
Overview of Factors Involved in the Mexico Earthquakes
The Mexico earthquakes provided many opportunities for learning. New knowledge has been obtained and continuing research will provide additional knowledge. The earthquakes have also demonstrated...
Damage Statistics of the September 19, 1985 Earthquake
Grupo ICA has participated in all stages of the actions and analysis of the effects of this quake aimed at taking advantage of this disastrous experience and has prepared a complete study...
Geotechnical Notes on the Effects of Mexico's 1985 Earthquakes
The present notes briefly describe the most relevant effects of the September 19 and 20, 1985 earthquakes on shallow and deep foundations used in Mexico City, which is located at about...
Effects of the 1985 Earthquake in Lazaro Cardenas, Mich.
An account is presented of a geotechnical survey made shortly after the major earthquake of September 19, 1985 (magnitude 8. 1) at the industrial port of Lazaro Cardenas in the state of...
Earthquake Response of La Villita Dam
Due to the recent industrial and housing developments at the port of Lazaro Cardenas, located 13 km (8 miles) downstream of La Villita Dam, at the mouth of the Balsas River, the hazard...
Analyses of Foundation Failures
During the earthquake of September 19th, 1985, many buildings tilted and underwent settlements, sometimes of very large magnitudes. This paper describes and analyzes these settlements....
Soil-Structure Interaction in Mexico City During the 1985 Earthquakes
The effects of the flexibility of the soil and the foundation on the seismic response of structures, by opposition to clear foundation failures, cannot be easily identified from a simple...
Performance Characteristics of Structures, 1985 Mexico City Earthquake
The 1985 Mexico City earthquake caused major damage to buildings, but not other structures, in the center of Mexico City, located approximately 400 km. from the epicenter. Due to soil...
Preliminary Dynamic Analyses of the Ministry of Agriculture Building
The Ministry of Agriculture building on Avenida San Antonio Abad was originally constructed as a 17 story reinforced concrete structure using a waffle slab system with interior reinforced...
Implications of Structural Characteristics on Failure
Performance of buildings with two common structural types, many of which suffered heavy structural damage or collapse, are analyzed. Conclusions are drawn that no structural type is inadequate,...
Observations on Structural Pounding
In over 40% of the collapsed or severely damaged buildings in Mexico City, pounding of adjacent buildings occurred, and in at least 15% was the primary cause of collapse. The main objectives...
Return to search