Engineering a Monument, Evoking a Nightmare
Rather than simply standing as a backdrop for exhibits, the $53.2 million U.S. Holocaust Memorial Museum is intended to be part of the fabric of the exhibition itself. Now under construction...

A feasibility study for a Concrete Core Tomographer
This is a study of the feasibility of applying computer tomography in the study of concrete cores. A laboratory protocol is presented for testing concrete cores using a medical - grade...

Real-Time Condition Monitoring of Concrete Structures by Embedded Optical Fibers
Fiber optic sensor methodology has matured to the point where the impact of this new technology is now evident, especially in aeronautics and space structure applications. External perturbations...

Concrete Beam Testing with Optical Fiber Sensors
The use of an embedded multimode optical fiber to monitor curing and load-to-failure testing of a reinforced concrete beam has been investigated. The embedding process used to network...

Sonic NDE of Structural Concrete
Case histories are presented to illustrate applications of nondestructive evaluation (NDE) methods that use stress waves to characterize the conditions of concrete construction. The case...

Evaluation of Concrete Bridges by Impact-Echo
Strength of post-tensioned bridge structural members primarily depends on the tensile capacity of their post-tensioning steel reinforcement. To prevent corrosion, the post-tensioning steel...

A Critique of the Ultrasonic Pulse Velocity Method for Testing Concrete
The pulse velocity method is the most widely used ultrasonic nondestructive method for assessing concrete quality. However, it has been well established that the relation between ultrasonic...

Evaluation of Compressive Strength for High-Strength Concrete by Pulse Velocity Method
Development of compressive strength and pulse velocity for high-strength concrete from the age of 5 hours are studied in relation to cementitious material types and curing conditions....

Condition Monitoring of Structures Using Transient Response
Condition monitoring of structures by measuring transient response and tracking the derived modal parameters has been applied with success in three laboratory studies. Where modal parameters...

Numerical Simulation of Dynamic Shear Transfer
This study was focused on the dynamic response of concrete interfaces under the effects of impulsive loads, and the relationship between the interface shear transfer and the response in...

Nondestructive and Destructive Testing of a Three Span Skewed R. C. Slab Bridge
A three span, skewed, reinforced concrete slab bridge was field tested to destruction by the authors. Before the actual destructive test, nondestructive tests were performed to determine...

Simulated Field Trials of Non-Destructive Concrete Test Methods for Highway Structures
The data presented results from a two year Strategic Highway Research Program investigation into suitable NDT methods for determining the early age, and residual strengths of highway structures....

Nondestructive Crack Identification by Acoustic Emission Analysis and Ultrasonic Frequency Response
Nondestructive evaluation (NDE) by the acoustic emission (AE) analysis and the ultrasonic testing (UT) on the spectral (frequency) response is studied to identify crack geometry. AE waveform...

Review of NPP Concrete Degradation Factors and Assessment Methods
Degradation of concrete in nuclear power plant (NPP) structures can be an age-related phenomena. Several research programs have been initiated by the U.S. Nuclear Regulatory Commission...

Pullout Testing of High-Strength Concrete Members
An experimental investigation of a high-strength concrete mixture was undertaken to measure and evaluate pullout and compressive strength properties. Two columns, a slab, and cylindrical...

Concrete Surface Characterization Using Optical Metrology
The displacement of the surface of a concrete specimen is measured as it cures using an optical method. This method, known as optical metrology, is one in which a line is projected onto...

Shrinkage Measurements in Composite Beam Slabs
When the concrete slab on a composite beam shrinks, it is restrained by the steel beam to which it is connected. Tensile stresses, as a result, are developed in the restrained concrete...

Collective Excellence
Building Effective Teams
Collective Excellence: Building Effective Teams is the second volume in the ASCE Engineering Management Series. Within the series focus of...

Probabilistic Mechanics in Civil Engineering
This paper describes the background, purpose and activities associated with the ASCE Engineering Mechanics Division and its technical committees. This includes research in probabilistic,...

On the Influence of Seismically Induced Residual Forces on Bridge Abutment Design
The seismic design of bridge abutments depend on the anticipated movement of the abutment during the design earthquake. For seat-type abutments in which the backfill resistance can be...

 

 

 

 

Return to search