Risk Analysis Applications for Dam Safety
Dam safety modifications are intended either to reduce the likelihood of the adverse consequences of dam failure or the magnitude of adverse consequences. For instance, widening a spillway...

Seismic Analysis of the Bonneville 1st Powerhouse
The Bonneville 1st powerhouse monoliths were constructed during the period of 1938 to 1942 and were designed against seismic loads using the old lateral coefficient method. The Corps of...

Cone Penetration Testing: Cost Effective Soil Exploration
On reviewing the 1987 Part 12 Dam Safety Inspection Reports for the Wisconsin River Power Company's Petenwell and Castle Rock Dams, the Federal Energy Regulatory Commission...

Effects of Uplift on a Gravity Arch Dam
This paper evaluates the behavior of a gravity arch dam when subjected to normal static loads and internal hydrostatic pressure (uplift). The ability to model uplift has become necessary...

Brule Hydroelectric Project Inflow Design Flood Study
In 1987, Wisconsin Electric Power Company (WE) was directed by FERC to provide additional spillway capacity at it's 63-foot (19 m) high Brule Dam. Original spillway capacity...

Analysis and Stabilization of Ambursen Dams?Two Case Studies
Case studies are presented about the analysis and rehabilitation of two slab-and-buttress (Ambursen) dams. The paper discusses the investigation techniques used, including sampling of...

Three Dimensional Modeling of Concrete Dams with Cracks Using Boundary Element Methods
Determining uplift pressure distributions in cracks in a concrete dam requires coupling between crack hydraulics and the stresses and displacements occurring in the rock and the concrete...

Penstock Monitoring System in Active Landslide Areas
During initial planning of a high-head, five megawatt hydroelectric plant in Northern California, it was identified that the entire three-mile length of a 40 inches welded steel penstock...

Dardanelle Turbines
The Dardanelle turbines located at river mile 205.5 of the McClellan-Kerr Arkansas River Navigation System, are experiencing an unusual amount of wear in the blade trunnion bushings. Oil...

Diagnostic Testing and Repair of Grand Rapids Generating Station's Unit Four
This paper is a case history that discusses diagnosis and correction of a variable pitch propeller type (Kaplan) hydraulic turbine problem. The turbine problem involved fatigue failures...

Pressure-Time Method Using Modern Practices
Over the past twenty years, Hydro-Quebec has modernized the pressure-time method of flow measurement, a method which is generally economical but sometimes difficult to apply. Starting...

Application of Personal Computers to Field Flow Measurement
Flow measurements are often necessary to verify the performance of hydro turbines for regulatory, contractual, or engineering purposes. Historically, several methods utilizing various...

History of Lysimeter Design and Use for Evapotranspiration Measurements
Lysimeters are devices for measuring percolation of water through soils and sampling soil water for chemical analyses. Lysimeters have been used for over 300 years to determine water use...

Precision Lysimetry in France
After a definition of the parameters to be measured, a possible reasoning is presented for the construction of a weighing lysimeter. A number of factors have to be taken in account: the...

Lysimeter Techniques and Application in India
Water is the most important resource and limiting factor for crop and industrial production in India, and agriculture is the largest consumer of water. The measurement of evapotranspiration...

Australian Lysimeter Studies of Field Evaporation
Evaporation data are summarised from separate lysimeter installations involving forest, crops and pastures along the 35?S parallel in south-eastern Australia. In each study, lysimeter...

Comparation of Different Forms of Penman Equation
The research was carried out near Foggia (in Southern Italy) at 90 m above sea level and at 41? 27' N latitude, using two drainage lysimeters, filled with a silt clay soil...

Lysimeters: Data Acquisition and Analysis
Lysimeters provide the most direct method for measuring evapotranspiration (ET). For ten years we have used weighing lysimeters capable of a resolution equivalent to 0.02 mm of water....

Representativeness of Floating Evapotranspirometers
In the first part of the paper, the design, the working principle and the field installation of floating evapotranspirometer are described with the data logging system which delivers continuous...

Accuracies of Lysimeter Data Acquisition Systems
Electronic dataloggers are integral parts of most weighing lysimeter systems. Dataloggers supply excitation voltages to lysimeter load cells and measure resulting voltage signals. Resolution...

 

 

 

 

Return to search