Caring for a Covered Bridge
Today the quaint Cornish-Windsor covered bridge (winner of this year's Outstanding Civil Engineering Merit Award) doesn't look much different than it did when...
Lifeline Earthquake Engineering at the Turn of the Century
The author considers it a singular honor to be the first recipient of the C. Martin Duke Award under the auspices of the Technical Council on Lifeline Earthquake Engineering (TCLEE) of...
Lifeline Earthquake Engineering in Japan: A State-of-the-Art
This is a subjective state-of-the-art report on the lifeline earthquake engineering in Japan. Beginning from the difference between civil engineering and building engineering in Japan,...
Lifeline Earthquake Engineering?A New Zealand Perspective
This paper outlines the application of earthquake engineering to New Zealand's lifelines, tracing the development of design practices in roading, bridging, power generation...
Recent Advances in Seismic Design and Retrofit of California Bridges
This paper describes the damage and lessons learned from the most recent major earthquakes, the resulting bridge seismic design and detailing changes and the seismic retrofit program implemented...
Earthquake Considerations in Design of the Los Angeles Metro
This paper discusses the earthquake design of the Los Angeles Metro. The design earthquake parameters are presented and discussed in light of the behavior of buried structures subjected...
Seismic Design for Port of Los Angeles, 2020 Program
Due to the Port of Los Angeles' (POLA) importance as a regional hub for transportation and commerce and the potential for a major seismic event in the Southern California...
Seismic Retrofit of Highway Bridge Structures
The California Division of Structures began its column retrofit program in 1986. This program is a supplement to the earlier superstructure retrofit program. Analysis and design concepts...
San Francisco Double-Deck Viaduct Retrofits
Following the Loma Prieta Earthquake in October 1989, six double-deck reinforced concrete viaducts in San Francisco were closed because of some isolated damage, and as a precaution for...
Retrofitting Northwest Connector for Seismic Forces
Many pre-1971 bridges in California have inadequate seismic resistance due to non-ductile components or poor connectivity of superstructure elements. Caltrans has finished the first retrofit...
Bridge Seismic Retrofit Prioritization
This paper describes a mathematical model developed to produce an index by which bridges in a network can be prioritized systematically for seismic retrofitting. The model incorporates...
Screening Procedures for the Retrofit of Bridges
Since the October 1989 Loma Prieta Earthquake in Northern California, interest has revived in seismic criteria for both new design and the retrofit of existing highway bridges. This interest...
Response of Ductile Iron Pipelines at Parkfield, CA to Loma Prieta Earthquake
A field experiment designed to investigate the performance of buried pipelines at a fault crossing has been constructed at Owens' Pasture near Parkfield, CA. The site was...
Scenario for Improving the Seismic Resistance of Pipelines in the Central United States
A number of pipelines transporting crude oil and natural gas to the Midwest and Northeast pass within and adjacent to the New Madrid seismic zone in the central United States. A major...
Seismic/Geologic Risks as Factors in Prioritizing Gas Pipeline System Replacement
During the past decade, Pacific Gas and Electric Company (PG&E) has intensified efforts to evaluate earthquake hazards and their potential effects on gas and electric power systems,...
Regional Risk Assessment of Environmental Contamination from Oil Pipelines
This paper presents a methodology for assessing the risk of environmental contamination from oil pipeline leaks due to earthquakes. Risk is measured both as volume of oil released and...
Seismic Hazard Along a Crude Oil Pipeline in the Event of an 1811-1812 Type New Madrid Earthquake
This paper presents an assessment of the seismic hazard that exists along a major crude oil pipeline (pipeline 22). An 1811-1812 type New Madrid earthquake with moment magnitude 8.2 is...
Aseismic Calculations for Transmission Towers
In this paper, mechanical models for long-span transmission line systems under elastic and gravitational restoring forces are established in three different directions; this continues...
Design of Substation Foundations for Liquefaction
When substation foundations penetrate liquefiable strata within risk prone seismic regions, the potential loss of support must be evaluated with state-of-the-art methods to determine foundation...
Earthquake Evaluation of a Substation Network
The impact of the occurrence of a large, damaging earthquake on a regional electric power system is a function of the geographical distribution of strong shaking, the vulnerability of...
Return to search