Mechanics of Crack Propagation in Stiff Clays
Many stiff clays forming part of natural slopes and earth dams exist in the fissured state. When these cracks are subjected to gravity induced normal and shear stresses they may propagate....
A Laboratory Investigation of the Undrained Small Strain Behavior of London Clay
Three different total stress-paths were followed during shearing of the anisotropic consolidated (CAU) tests: compression, extension and a stress-path simulating an element under a plate...
Lateral Pressure in a Stiff Clay
A series of consolidated undrained and drained triaxial tests and oedometer tests were performed on horizontal and vertical specimens taken from an overconsolidated cretaceous clay. An...
Excavation in Hard Clays of the Keuper Formation
For the construction of a lock on the Main-Danube-Canal in South Germany a 30 m deep cut had to be excavated in the overconsolidated clays and claystones of the Keuper formation. The strength...
Preliminary Seismic Risk Maps for Puget Sound
Ground shaking during Puget Sound earthquakes is characterized by irregularly shaped areas of high intensity ground motion, not all of which are correlated with soil type. Simulation of...
Seismic Acceleration Maps for Oregon
To evaluate the seismic hazard for the Corps dams in the Portland District, operating basis earthquakes (OBE) and maximum credible earthquakes (MCE) were established for seismic zones...
Seismic Risk Assessment for a Utility System
Presented is a procedure by which a utility could develop the probabilities for different levels of capital loss exposure for its system. The procedure relies on experience data obtained...
Seismic Risk Analysis System
The Seismic Risk Analysis System was developed to model the expertise of experienced engineers and researchers and to provide consultation to the users. The Seismic Risk Analysis System...
Design and Planned Use of a 2-Kiloton Eccentric Mass Vibrator
High-level testing of large civil structures is usually not practical, due to structural damage considerations and available testing equipment. However, in the case of a joint American/German...
Attapulgite: A Clay Liner Solution?
Poor performance of clay liners at waste management facilities has resulted in the EPA mandate of synthetic polymeric liner materials to comply with zero penetration requirements. Laboratory...
U.S.-Japan Coordinated Program on Masonry Research
An overview of the U. S. -Japan Coordinated Program on Masonry Research is presented. The program consists of parallel efforts in Japan and the United States to develop design methods...
Importance of Phasing of Strong Ground Motion in the Estimation of Structural Response
In this paper, the influence on Fourier phase spectrum of seismic source directivity due to rupture propagation along the earthquake source is investigated. The phasing is described using...
Dynamic Testing of Structures Using the RESCUE Technique
This paper describes the most recent phase of an NSF supported program at SRI International to develop the technique of repeatable earth shaking by controlled underground expansion (RESCUE)...
Pseudo-Dynamic Testing of Structural Components
The pseudo-dynamic testing procedure is a simultaneous simulation and control process in which inertia and damping properties are simulated and flexibility properties are acquired from...
Seismic Tests of Friction Damped Steel Frames
This paper presents the results obtained from qualification tests of a new friction damping system, which has been proposed in order to improve the response of Moment Resisting Frames...
Hysteretic Behavior of Composite Diaphragms
Floor systems constructed with steel-deck-reinforced concrete are described. When used to resist lateral loads these systems are referred to as diaphragms. A description of a test arrangement,...
Precast Roofs for Blast Shelters
A shallow-buried reinforced concrete blast shelter has been constructed and dynamically tested at the U. S. Army Engineer Waterways Experiment Station (WES). Three thicknesses of precast...
Field Tests of Wind-Structure Interaction
The present study was initiated to investigate the possible causes for excessive lamp failure rates on High Mast illumination towers in the State of Minnesota. The study consisted of two...
Vibration Tests of Reservoir Structures Outlet Tower and Footbridge
This paper presents a field test procedure used in determining the dynamic properties of an outlet tower and footbridge for a major reservoir. Such factors as virtual water mass, soil-structure...
Dynamic Tests of LNG Storage Tanks for Earthquake Analysis of Liquid-Tank-Pile-Soil Interaction
This paper presents a field test procedure for determining the dynamic properties of large liquid natural gas (LNG) storage tanks under operating conditions. Two methods of vibratory excitation...