Transient Dynamic Response Analysis of Embedded Rigid Foundations
A simplified approach for the transient dynamic response analysis of embedded multiple rigid foundations is presented. The approach is based on approximate time-domain formulations of...
Subgrade Model for Static and Dynamic Response Analysis of Surface Foundations
A new subgrade model is presented for the static and dynamic response analysis of surface foundations. The model consists of a number of horizontal layer model units. Each model unit is...
Foundation Studied for Turbine-Generator on Liquefiable Soils
Turbine-generator foundations are generally constructed of concrete in the U.S.A. This paper deals with the dimensioning and evaluation of a turbine foundation in Oxnard, California. The...
Ground Failure Damage to Buildings During Earthquakes
Several case histories are examined to evaluate building damage as a function of the foundation type and type and amount of ground displacement. Extensional or vertical ground displacements...
Simplified Seismic Analysis of Pile Foundations
The determination of displacement of the pile cap and displacements and forces of individual piles is essential to the design of pile foundation subject to both static and/or dynamic loading....
Seismic Response Considerations in Foundation Design
There are no generally accepted procedures to determine the potential magnitude of reduction of footing bearing capacity that may result from soil strains or pore pressure changes during...
Risk Correction Factors for Bearing Capacity Analysis
In this paper bearing capacity correction factors are developed to account for the randomness in the load and soil properties. These are applied to the bearing capacity equation in the...
Human Factors and Communication Problems in Foundation Engineering
Recent findings in non-engineering fields related to human factors are reviewed with emphasis on communication difficulties. Foundation engineering tasks are discussed in the context of...
Geotechnical Judgment in Foundation Design
This paper summarizes the initial findings of a research project to investigate the judgment-making process of foundation engineers. Solutions for a typical design problem were solicited...
Analysis of Pile Load Tests at Lock and Dam 26
This is a summary of the results collected during the extensive load test program performed by the U.S. Army Engineer District, St. Louis, during the construction of the new Lock and Dam...
Comparative Performance of Two Pile Types
This paper reports on the pile driving and load bearing characteristics of the two pile types driven at a plant site in Sumatra, Indonesia. Nine prestressed concrete piles were driven...
Bearing Pressure?SPT Correlations for Expanded Base Piles in Sand
Design of enlarged base piles is usually carried out using correlations between SPT N values and point resistance. The results of full scale load tests are used to show that base resistance...
Contribution of Soil Freeze to Pile Capacity
In order to investigate the magnitude and rate of increase in load capacity for piles installed in clayey soils, a series of load tests were performed at various intervals of time following...
Some Observations on Undrained Side Resistance of Drilled Shafts
A data base of 106 field load tests (65 in uplift and 41 in compression) is used to evaluate the undrained side resistance of drilled shaft foundations. The total stress or alpha (?) method...
New Design Method for Drilled Shafts from Common Soil and Rock Tests
A method is presented by which the compressive capacity and load-settlement characteristics of large drilled shafts can be computed from commonly executed soil and rock tests. The method...
Performance of High Capacity Caissons Founded on Decomposed Rock
The results of six load tests on large diameter caissons founded on decomposed rock are presented and analyzed. The caissons ranged from 1.5 m to 2.5 m in diameter and were 20 m to 23...
Load Tests on Bored Friction Piles in Clay
For the first time in Boston, Massachusetts, U.S.A., uncased bored friction piles in clay were used to support a six-story residential structure over a 60- to 75-foot (1.83 to 22.9 m)...
Skin Friction Load Test for Caissons in Residual Soils
Results of a load test on a drilled pier are presented. The test was performed to measure only skin friction of a 36 inch (0.91 m) diameter shaft without support at the end. The load test...
Full Scale Caisson Load Test for the Milwaukee Center
Top-down procedures were proposed to construct four basement levels for a major high-rise building development in Milwaukee, Wisconsin. Drilled caisson foundations were the preferred means...
Drilled Shafts?A Database Approach
A database of 43 drilled shaft load tests of high quality has been developed to study parameters that affect the axial behavior of drilled shafts and methods of analysis to predict axial...