Reliability Analysis of Levee System of a River
The levee height is determined by the summation between computed water level and an assumed freeboard. The water level is computed by given discharge in the steady conditions. Therefore,...

Uncertainty Analysis of the FEMA Method for Alluvial Fans
Distributary flow areas such as alluvial fans, bajadas, and alluvial slopes, and alluvial plains along mountain bases pose quite different and interesting problems for the design of hydraulic...

Three-Dimensional Modeling of the Coastal Region Offshore from Sydney, Australia
Care must be taken in model formulation to ensure that unwanted internal circulation cannot be induced. Extensive model testing must be carried out on possible distorted element shapes...

New York Bight Three-Dimensional Water Quality Model
The numerical modeling technology developed for Chesapeake Bay was applied to the Middle Atlantic Bight extending 550 km form Cape May, NJ, northeasterly to Nantucket Island, MA, and extending...

Serviceability Stress Limits for Composite Beams
Serviceability limits are increasingly becoming the critical design requirement for composite beams. A set of three illustrative design studies indicates that this is particularly true...

Connection of Grouted Tubular Insert Piles to Soil
Force transfer between offshore production jackets and tubular piles is effected by weld bead shear connectors, acting within the grout filled annulus between the piles and pile sleeves...

Design of Composite Slabs for Vertical Shear
Three major modes of failure should be considered in the design of the positive moment regions of composite slabs incorporating profiled steel sheeting, viz.: flexure, longitudinal slip...

Cyclic Lateral Load Analysis of Composite Frames
A method of analysis for composite building frames subjected to repeated and reversed lateral loads has been developed as part of an overall investigation of seismic response of composite...

Semi-Rigid Joint Action in Composite Frames: Numerical Analysis and Design Criteria
The paper focusses on the analysis of semi-rigid composite frames, reporting mainly on the results of a research study which combines the experimental and theoretical approaches. Attention...

Investigation of Corners and Joints Applied to a Steel-Concrete Composite Caisson
We have developed a caisson composed of steel-concrete composite slabs and steel structures, which we call a `Hybrid Caisson.' We studied the structural principles and usability of the...

Composite Columns Subjected to Bending and Shear
This paper describes experimental as well as analytical studies of the post elastic deformation and fracture behaviors of wide flange steel encased reinforced concrete (SRC) composite...

Full-scale Tests on Composite Connections
Tests have been carried out on eight full-scale composite connections in which the columns were manufactured of concrete-filled steel circular hollow sections (CHS). The connections were...

Behavior of Concrete-Filled Steel Tubular Three-Dimensional Subassemblages
Three-dimensional subassemblages consisting of a concrete-filled steel tubular column and four H-shaped beams were tested under a constant axial load on the column, constant beam loads...

Numerical Analysis of Composite Slab Behavior
A new calculation procedure is described which provides an alternative to full-scale testing for composite slabs with ribbed decking used in buildings. This procedure consists of combining...

New Steel Beam to Composite Column Connection Detail
Composite columns consisting of hollow steel tubes filled with high strength concrete with compressive strength exceeding 10000 psi (69 MPa) are being used in high-rise buildings. Connecting...

Effects of Connections on Composite Frames
This paper summarizes the preliminary findings from an experimental and theoretical study of the influence of composite connections on frame behaviour. The first part of the work included...

Townsite Lateral-Stage 2 Belle Fourche Unit - Cheyenne Division Concrete: Pipe with Dumped Bedding and Embedment
In 1933, M. G. Spangler presented three bedding configurations and the concept of a bedding factor to relate the supporting strength of buried concrete pipe to the strength obtained in...

PCCP Inspection and Remediation Methods
This paper presents detailed investigative procedures and methodology used to locate corroded Prestressed Concrete Cylinder Pipes (PCCP). It examines data collection by electronic devices,...

Pipeline Leak Detection Based on Mass Balance
Current technologies in Supervisory Control and Data Acquisition (SCADA) systems enable pipeline leak detection to be carried out in real time by software-based methods. This paper discusses...

Analysis of Pavement-Pipeline Systems After Cut Restoration
The placement of utility pipes normally necessitates many cuts and fills of the existing pavements. Integrity of pipeline and compatible performance of cut restoration and original pavement...

 

 

 

 

Return to search