Testing of Reinforced Concrete Bridges for External Reinforcement
Several continuous reinforced concrete slab bridges were constructed in the 1950's with spans ranging from 30 ft. to 60 ft. Longitudinal cracks were observed in the tension...

Sulfate Attack on Concrete Containing Fly Ash
The use of fly ash as a portland cement replacement in concrete may provide many technical and economic advantages. One such technical advantage is to improve the resistance of concrete...

Freezing and Thawing Durability of High Strength Silica Fume Concrete
Specimens from 27 batches of concrete with a water to cementitious (cement plus silica fume) ratio of 0.25 to 0.32, with and without entrained air, were tested for freeze-thaw durability...

Service Life of Underground Concrete Structures
The service life of underground concrete depends on both the physicochemical properties of the concrete materials and the properties of the in-service environment. The major factors controlling...

Fiberglas Reinforced Plastic Rebars in Lieu of Steel Rebars
Fiberglass reinforced plastics have recently been introduced in the market in the form of rebars for concrete reinforcement. The light weight, corrosion resistance and non-magnetic properties...

Enhancing Concrete Durability by Treatment with Sealers
This paper summarizes some of the research which has been undertaken on sealers for hardened concrete during the last ten years at Wiss, Janney, Elstner Associates. Inc. The research used...

Surface Treatments for Concrete
The US Army Corps of Engineers initiated in 1984 a research program designated Repair, Evaluation, Maintenance, and Rehabilitation (REMR), one of the work units being the evaluation of...

The Use of Penetrating Sealers on Concrete Bridge Decks
Acceptance criteria for Penetrating sealers is shown. Penetrating sealers can be used as cost effective preventive maintenance for bridge deck concrete in northern climates. Factors affecting...

Evaluation and Remediation of Construction Defects in Tilt Wall Panels
Both the surface appearance and structural safety were of concern to the Owner of a five year old warehouse structure that was experiencing delamination of tilt-up wall panels. Delamination...

High Molecular Weight Methacrylate for Sealing Cracked Concrete
The sealing of cracks in concrete surfaces has been one of the most difficult types of repair to accomplish. Epoxy injection has been widely used, but due to its relatively high cost,...

Concrete Residential Construction in Baja, Mexico
Mexicali, Mexico has experienced earthquakes of magnitude 6.0 to 7.6 on the Richter Scale. A popular and readily available residential construction material is reinforced concrete comprised...

Fatigue of Reinforcement in Partially Prestressed Beams
A summary of the findings of an extensive experimental program on the fatigue characteristics of partially prestressed concrete beams is described. It is observed that the stress range...

A Summary and Review of Fatigue Data for Mechanical and Welded Splices in Reinforcing Bars
Published reports pertaining to fatigue tests of welded and mechanical splices in reinforcing bars were reviewed. It was observed that most specimens fractured in the reinforcing bar adjacent...

Fatigue Strength of Welded Steel Mesh
Welded steel mesh (WSM) is prefabricated by welding cold-drawn wires in a grid-like mesh. Engineers avoid using WSM as main reinforcement in highway structures due to their lack of knowledge...

Concrete Strength-Quality Assurance
The usual criterion for establishing grades of structural concrete is the compressive strength measured in an arbitrary manner on a standardized specimen stored in a stipulated fashion...

Early Age Strength Detection for In-situ Concrete
In recent years it has become increasingly beneficial to know the quality of concrete as soon as possible after it has been placed. This is especially true for high-rise concrete buildings...

Fast-Track Concrete Paving
Well known for its corn production, the State of Iowa has been seeding a new product for the past several years. 'Fast Track' concrete has grown along the edge...

Early Opening of Concrete Pavements to Traffic
Current practice for opening slab replacements and full-depth repairs to traffic ranges widely from 2 hours to several days. A rational and simple procedure is urgently needed for determining...

Lessons Learned in Laboratory and Field Evaluation of Accelerated Strength Tests for Quality Control of Concrete Pavements
This paper describes the results of an accelerated strength testing program performed to evaluate flexural strength potential at 28- and 90-days. Based upon a literature review of previous...

Application of Fiber-Composites in Civil Engineering
Two potential applications of Glass-Fiber-Reinforced-Plastics (GFRP) in civil engineering type structures are investigated: (1) GFRP rebars in concrete beams; (2) strengthening of concrete...

 

 

 

 