Horizontally Curved Steel Bridge Research-Update 2
Theory and data necessary for the development and calibration of an LRFD based curved steel bridge specification do not presently exist. To address these needs, the Federal Highway Administration...

Design Implications of Advanced Analysis in LRFD
This paper discusses two advanced analysis methods, and their use in LRFD format. The first approach is called the notional load plastic hinge method and the second is called the second-order...

Seismic Issues in Structural Engineering Codes and Practice
It is necessary that we view the seismic events in an overall probabilistic mode and determine the criteria for acceptable damage at various levels of service in the building. We need...

Response Study of a Flexible Building Using Three Earthquake Records
This paper examines the response of a flexible building during three earthquakes. The records from the building are long and contain low frequencies. The site frequency (0.33-0.38 Hz)...

Seismic Response and Retrofitting of Non-Ductile Reinforced Concrete Bridges
The Interstate I5/I605 Separator in Los Angeles County was severely damaged during the October, 1 1987 Whittier Narrows Earthquake. This damage included non-ductile shear failure in the...

Seismic Upgrades Using Energy Dissipation Devices
This paper presents a model for developing comparative seismic rehabilitation schemes for essential facilities using both conventional techniques and passive control devices. Essential...

Implementation of Passive Energy Dissipation Systems in the United States
Significant advances in the field of passive energy dissipation for improved structural seismic resistance have been made in recent years. Developments in research and analysis techniques...

Utilizing Visco-Elastic Dampers in the Seismic Retrofit of a Thirteen Story Steel Framed Building
A 13 story steel framed building in Santa Clara Country, California exhibited strong beating effects (torsional coupling) and prolonged building response as result of various seismic events....

Hi-Tech Seismic Rehabilitation of `Casino De Montreal'
The existing eight-story steel structure, built during 1966, lacked in lateral earthquake resistance and ductility requirements of the current building code. Introduction of friction-dampers...

Tests of Full-Size Pretensioned AASHTO Beams with Debonded Strands
A summary of an experimental investigation dealing with the effects of strand debonding on the flexure and shear behavior of simply supported pretensioned AASHTO beams with a cast-in-place...

Anchorage of Non-Metallic Prestressing Tendons
Experimental confirmation tests were conducted to evaluate mechanical and epoxy socketed anchors for fiber reinforced plastic (FRP) prestressing tendons. The studies found that a parabolically...

A Generalized Approach to the Local Stability of Stiffened Plates: Part I?Mathematical Formulation
The paper describes a generalized approach for the determination of the buckling stress of stiffened plates under combination of uniform biaxial compression, in-plane bending and shear...

A Generalized Approach to the Local Stability of Stiffened Plates: Part II?Approximate Solution
The paper presents an approximate solution for the prediction of the buckling stress of stiffened plates under combined loadings. A closed form expression is presented for the buckling...

Messeturm Tower: Frankfurt, Germany
A 256 meter (840 feet)tall office tower, currently the tallest building in Europe, has been constructed in Frankfurt Germany. The 7- story structure with 85500 square meter (920,000 square...

LRFD vs. ASD for Wood Structures
There is a growing preference within the structural engineering community for the adoption of reliability-based load and resistance factor design (LRFD) procedures in lieu of traditional...

AWS versus AIJ Tubular K-Connection Design Rules
Among various existing design rules for circular tubular connections, the AWS rules are compared with the AIJ rules because of differences between the two. Subjects of discussion include...

Expandable Structures with Incorporated Roofing Elements
In this paper design aspects of expandable structures with incorporated cover plates are studied. These roofing elements can be made by single plates or by self-folding plates. In both...

Punching Shear of Reinforced Concrete Shell Structures
In reinforced concrete shells punching shear failure may take place, if heavy concentrated loads are applied. Such failure is undesirable, since it does not provide adequate warning and...

How to Optimize Frames Using Plastic Design Concept
An optimal design procedure using plastic design concept was presented. For low-rise building frames, optimal plastic designs can be made using the plastic limit load as a basis of design....

Generalized Optimal Active Control with Embedded and Half-space Soil-Structure Interaction
The paper presents an optimal active control algorithm with soil-structure interaction for seismic response. By using an intelligent device in the feedback gain matrix, the algorithm can...

 

 

 

 