Robust Control for Buildings Under Earthquake
Robust control techniques are applied to civil engineering structures subjected to earthquake excitation. Full state feedback and observer based control laws are used to reduce the response...

Passive Energy Dissipation Systems for Earthquake-Resistant Design
Passive energy dissipation devices, also known as supplemental damping devices, have been proposed as a means by which the earthquake resistance of a building can be substantially enhanced,...

Recent Developments in Seismic Isolation Technology
Large experimental research projects for isolators for both civil structures and nuclear reactor applications have been conducted at the Earthquake Engineering Research Center (EERC) over...

Seismic Isolation Retrofit of the State of California Justice Building
The State of California Justice Building, located at 350 McAllister Street, San Francisco, is the first building to be selected by the State of California for retrofit using seismic (base)...

Seismic Performance of Base-Isolated Building Structures
The theories and assumptions behind the base isolation technology are briefly described. As an illustration of its application, the base isolation of an existing 12-story hospital in Long...

Seismic Base Isolation Design for the San Bernardino County Medical Center Replacement Project
The SBCMC Replacement Project, located in Colton, California, consists of six separate building structures containing a total of approximately 86,000 m2...

Analytical Studies on the Seismic Response of Lead Rubber Base Isolated Bridges
Highlights of a study related to the response of base isolated bridges are presented. Four different analytical models are developed and used to evaluate the response of base isolated...

Dynamic Analysis of Sliding Seismic Isolators
The friction pendulum system (FPS) sliding seismic isolators are being used for the seismic isolation rehabilitation of the U.S. Court of Appeals Building, San Fransisco. This paper will...

Structural Reliability of Seismic Isolation System
Seismic reliability analysis of isolated structure is conducted. In this study focused on are bearing capacity of isolation layer considering strength randomness of isolation bearings...

Vibration Control of Highway Bridge Under Earthquakes
Seismic base isolation for highway bridges may increase relative displacement, while reducing the acceleration and base force. Elastomeric bearings with lead plug for base isolation may...

Exact Nonstationary Response of a Sliding Rigid Structure to a Modulated White Noise Base Excitation
The seismic design of embankment dams, earth retaining walls and base isolation systems have emphasized the dynamic analysis of a rigid block sliding on a moving base. In an early study...

Seismic Surgery Rewarded
By installing isolators in the columns and strengthening the frame, engineers upgraded an eight-story concrete office building in Seal Beach, Calif. so that it should continue to function...

Viscoelastomeric Connections in Seismic Structures
Nonlinear Kelvin and Maxwell impedances connect lumped masses to form arbitrary networks. Viscoelastomer-steel composite moment connections are modeled similarly, using auxiliary masses,...

Frictional Base Isolation Using a Layered Soil-Synthetic Liner System
The application of smooth geotextile liner materials to seismic base isolation of shallow foundations has been evaluated using laboratory testing and numerical analysis. Laboratory testing...

On Aseismic Hybrid Control System
One type of hybrid control system is proposed for protecting tall buildings subjected to strong earthquakes. The hybrid system consists of a base isolation system connected to either a...

Response of Sliding Base-Isolated Structures
Experimental and anlaytical results on the behavior of sliding isolated structures are presented. A mathematical model of friction of Teflon bearings is developed, calibrated, and verified....

Earthquake Energy Partitioning in Base Isolated and Dynamically Damped Structures
New earthquake energy spectra are proposed for practical design procedures using energy concepts. The spectra show integrated earthquake input energy of a unit mass with given natural...

A Study of Seismic Reliability of Base Isolated Building Comparing with Non Base Isolated Building
An approach to discuss the difference between reliability of base-isolated buildings and that of non base-isolated buildings is presented. The fragility analysis method in PRA procedure...

Response Variability of Isolated Structure Due to Randomness of Isolation Devices
Effect of randomness of restoring characteristics of an isolation device, which is considered to result from the randomness of material properties, configuration and setting error, on...

Seismic Surgery
The authors describe the installation of seismic isolators in the columns of an eight-story concrete building in Seal Beach, Calif., which serves as Information Systems Center for Rockwell...

 

 

 

 

Return to search