Preventing Stilling Basin Abrasion
A 1:10 scale physical hydraulic model of Taylor Draw Dam outlet works was used to develop modifications to prevent back flow intake of rock into the stilling basin. Much of the back flow...

Near-Field Differential Ground Displacement
An analytical model for the development of differential ground motions in the vicinity of a vertical, strike-slip fault is presented. The model considers a uniform, kinematic source model,...

Large Monte Carlo Simulation of Duffing Equation
This effort aims to obtain some accurate statistics of the Duffing Equation subjected to white noise through Monte Carlo simulation. The results obtained can be used to check the accuracy...

Ambiguities and Inanations of Current Plastic Pipe Specifications
This paper discusses current specifications, including materials for plastic pipe as compared to other pipe specifications, including rigid pipe materials. It discusses the ambiguities...

Short-Term Versus Long-Term Pipe Ring Stiffness in the Design of Buried Plastic Sewer Pipes
It is often discussed which pipe ring stiffness should be used when designing the long-term deflection of buried plastic sewer pipes; the short-term value or the long-term value? As the...

Synthesis of Studies for the Potential of Fault Rupture at the Proposed Surface Facilities, Yucca Mountain, Nevada
Published data for the Midway Valley area, the proposed site of the surface facilities of a high-level nuclear waste repository at Yucca Mountain, suggest that recognized regional faults...

Flexible Pipe Design Revisited
An overwhelming soil factor in the Iowa formula and random deformations at installation affords soil a prominent role in flexible pipe; this, together with a maximal deflection rule make...

Displacement Measurement by Laser Interferometry and Image Analysis
Laser holographic interferometry was used for the evaluation of displacement fields on concrete and fiber reinforced concrete specimens. Transmission holography was used to analyze mortar...

Aussie Steel
The 50-story Chifley Square Building being built in Sydney will be the tallest Australian steel building. Scheduled for completion in June 1992 at a cost of $310 million, it will house...

A Study of the Precision of Optimum Design Using Suboptimization
As the scale of structures becomes larger and their configuration become more complicated, the design variables and constraint conditions increase, and numerical calculation of the optimum...

Two-Level Optimization of Nonlinear Structures
This paper presents several optimization design problems and their applications to both cable structures and geometrically nonlinear braced-rib arches. The sum of squares of residuals...

Experience with the p-Version Program PROBE
The conventional approach in the FEM is known as the h-version, in which the solution accuracy depends on the size h of elements. The alternative approach is the p-version, in which the...

Application of BEM to Two-Dimensional EPFM
This paper describes the authors' current and continuing research in application of the Boundary Element Method (BEM) to crack growth problems in Elastoplastic Fracture Mechanics...

Behavior of a Crack Under Reversed Cyclic Loading
The results of two series of basic experimental studies for opening and closing behavior in RC members are reported. For the first series, axial forces were applied to the specimens in...

Fourier Series Expansion on Determination of Response Bound of Beam
Fourier series expansion is suggested to discrete the continuous vibrating system by regarding Fourier constants as generalized displacement parameters. The orthogonal merit to the terms...

Analysis and the Design of Multi-Layer Viscoelastic (V.E.) Dampers for Tall Structures
Vibrational motion of tall buildings can be damped by employment of viscoelastic passive dampers in the structure. The type of dampers selected depend on locations where relative displacements,...

Reliable Displacements from Integrated Quick-Release Accelerograms
A new baseline correction method has been developed which allows accelerograms collected during quick-release tests of full scale structures to be doubly integrated to displacements. The...

On the Critical Relative Displacement of Pile Shaft and Surrounding Soil
Model pile pull-out tests have been conducted to investigate the characteristics of the critical relative displacement at which the critical pile skin resistance is mobilized. Test results...

Ground Failure Damage to Buildings During Earthquakes
Several case histories are examined to evaluate building damage as a function of the foundation type and type and amount of ground displacement. Extensional or vertical ground displacements...

Monitoring the Effects of the Pipe Insertion Machine Technique
The results of an experimental study of the pipe insertion machine are presented in this paper. Strains induced in an adjacent pipeline, soil displacement, pipe deflection and vibrations...

 

 

 

 

Return to search