Composite Beams: Redistribution, Reliability, and Lateral Buckling
Research relevant to three aspects of the design of composite beams for ultimate limit states is summarized. These are: the redistribution in continuous beams and in framed structures...

Two Full-Scale Tests of Class 3 Composite Beams
This paper presents two tests of continuous composite beams comprising two 7.5 m spans and two concentrated loads close to the intermediate support. Although the cross-sections on the...

Shear Connection in Composite Beams
This paper considers the influence of the shape of the deck profile on the shear connection of composite beams. It was found that the existing strength reduction factor can be unconservative...

Serviceability Stress Limits for Composite Beams
Serviceability limits are increasingly becoming the critical design requirement for composite beams. A set of three illustrative design studies indicates that this is particularly true...

Composite Space Frame?Experimental/Analytical Study
This paper describes work carried out on a composite space frame system. The system, previously developed for roof construction, comprised a pyramidal arrangement of steel angles and circular...

Slim-Floor Beams: Design Criteria and Structural Behaviour
Partially concrete-encased steel beams are mostly employed due to their natural resistance to fire, but there may also be other reasons, e.g. to obtain smaller depths of construction....

Comparison of Simple Calculation Methods for the Fire Design of Composite Columns and Beams
There is a need for approximate calculation methods to do the fire design of composite structures. Several of such methods for composite beams and columns have been compared to find out...

Design of Shear Connectors in Composite Bridge Beams
A new approach is described for the design of stud shear connectors, in composite steel and concrete beams that are subjected to vehicular loads, which allows for the interaction between...

The Steel Deck Institute Method for Composite Slab Design
The Steel Deck Institute (SDI) of the USA has synthesized the composite slab research and testing that has been conducted in the U.S. during the past 25 years and has presented a design...

Cyclic Lateral Load Analysis of Composite Frames
A method of analysis for composite building frames subjected to repeated and reversed lateral loads has been developed as part of an overall investigation of seismic response of composite...

Ductility Effects of End Details in Composite Beams
A limit states criterion is described for quantifying the rotation capacity of members in indeterminate structures as a means of classifying ductility of structures during plastic behaviour...

Seismic Response of Composite Coupled Walls
In many structures, height restrictions may require coupling of reinforced concrete walls by structural steel beams rather than conventional reinforced concrete beams. Through an experimental...

Connection of Beam Flange to Concrete-Filled Tubular Column
Research has been carried out on a frame composed of a concrete-filled steel tubular column and H-shaped steel beam with the aim of developing a reasonable connection method. The proposed...

Full-scale Tests on Composite Connections
Tests have been carried out on eight full-scale composite connections in which the columns were manufactured of concrete-filled steel circular hollow sections (CHS). The connections were...

Steel Beams with Reinforced Concrete Stiffened Ends
For the construction of office building with long span beams, steel beams with reinforced concrete stiffened ends are being used in order to increase the stiffness. This paper describes...

Connections of Concrete Filled Steel Beams
The concrete between the steel flanges of composite beams leads to problems in the connection area. To solve these problems four new types of beam-girder and beam-column connections are...

Behavior of Concrete-Filled Steel Tubular Three-Dimensional Subassemblages
Three-dimensional subassemblages consisting of a concrete-filled steel tubular column and four H-shaped beams were tested under a constant axial load on the column, constant beam loads...

Application and Recent Development of a Numerical Model for Composite Beams with Partial Shear Connection
This paper deals with numeric analysis of composite steel and concrete beams for loads up to the ultimate beam capacity. Two versions of a numerical model are presented addressing such...

Influence on Steel Deck on Composite Beam Strength
Results of a recent study were described in which 7 push-out tests and 4 composite beam tests were conducted. The results were consistent with other recent studies reported in the literature,...

Composite Beams with Headed Studs in Narrow Ribbed Metal Deck
This paper presents the results of sixteen push-out tests conducted to study the behavior of headed stud connectors in composite beams with narrow ribbed metal deck placed parallel to...

 

 

 

 