Wet Mix Shotcrete Used in Subsea Tunnel Environments
To reject the claim that the use of accelerator in shotcrete reduces the compressive strength with time, lately cored samples were taken from an 18 to 19 years old concrete. A wet mixed...
The Influence of Water Glass on the Technological Parameters of Shotcrete
Shotcrete used in tunneling must follow a clearly defined early strength development in order to comply with stresses from rock deformations and drilling and blasting. Accelerators are...
Shotcrete Tests at the Fish Ecca Tunnel
The Fish-Ecca Tunnel is situated in the Eastern Cape and forms part of the Lower Fish Irrigation Scheme. About 25% of the 5032 m tunnel had to be lined with shotcrete. Between February...
Site Measurement of Shotcreting Dust
Shotcreting is broadly used today as an excellent lining system, which enables to assure rapidly the stability of excavated rock surface. This system however leaves room for improvements...
An Identity Chart for Steel Fibers
Improvements in ductility and toughness by adding steel fibers to the shotcrete mix are sufficient to enable steel fibers to be used as replacement for steel mesh reinforcements. Steel...
Steel Fiber Reinforced Shotcrete—For Rock Support and Fire Protection
Rapid development in concrete technology and development of equipment has led to a change from dry hand-operated to wet robot shotcreting in Norway. Shotcrete of more than 100 MPa cube...
Evaluation of Fiber Optic Bragg Grating Strain Sensor in High Strength Concrete Beams
Seismic Strengthening of R/C Columns Using Steel Jackets
This paper presents experimental results on the use of steel collars and steel jackets as a retrofitting system to improve the seismic performance of short rectangular reinforced concrete...
CenterCore Strengthening System for Seismic Hazard Reduction of Unreinforced Masonry Bearing Wall Buildings
The CenterCore technique of reinforcing unreinforced masonry walls was developed with the help of a National Science Foundation grant in 1984. The CenterCore strengthening system consists...
Earthquake Strengthening of a Twelve Story Non-Ductile Concrete Frame Building with Unreinforced Masonry Using Displacement Control Criterion
The structural concern with the Cooper Arms Apartment building when subjected to ground shaking was the in-plane and out-of-plane forces on the infill and consequences of the infill resisting...
Tension Pile Test
The California Department of Transportation is conducting FULL SCALE AXIAL LOAD TESTS of 34 piles. This research project/proof test is being jointly conducted by public agencies (Caltrans...
Seismic Behavior of Weak-Column Strong-Beam Frames
An experimental evaluation of the seismic performance of moment-resisting steel frames using Weak-Column Strong-Beam joints is described. A simulated seismic response is imposed on five...
Cyclic Behavior and Seismic Design of Steel Base Plates
The objectives of this study were to conduct realistic experiments to understand cyclic behavior of steel column base plates and to develop seismic design recommendations. Six specimens...
High-Strength Concrete Joints Under Cyclic Loading
This experimental investigation was undertaken to check the validity for high-strength concrete beam-column joints of recommendations made by ACI-ASCE (American Concrete Institute-American...
Orthotropic Rigidities of Curved Concrete Waffle Slabs
Analytical expressions are derived for predicting the flexural and torsional rigidities during the pre-cracking and post-cracking stages for horizontally- curved waffle slab structures....
Seismic Strengthening of Johnstown Tank in Lakeside, California
Seismic overturning moments exerted on liquid storage tanks may be resisted by a system of anchor bolts if the shell could be adequately anchored to its base, or by allowing the base plate...
Evaluation of Seismic Isolation Schemes for a Historic Building
The U.S. Court of Appeals Ninth District building originally completed in 1905 with an expansion in 1933, suffered damage during the 1989 Loma Prieta earthquake. The building is currently...
Seismic Strengthening for Structures in Regions of Low Seismicity
Most existing structures were not designed to today's seismic codes and standards, and in fact in low seismicity regions codes did not require seismic design until recently....
Axial Capacity of Concrete Infilled Steel Box Column with Biaxial Bending
The objective of this study was to investigate the feasibility of using the Bresler reciprocal load method to calculate the axial capacity of a concrete infilled steel box column subjected...
Composite Beams and Joists
Composite beams and joists used as flexural members in multistory steel-frame buildings are considered. Research results have shown that present design values for headed shear studs, used...