General
Design of Latticed Steel Transmission Structures specifies requirements for the design, fabrication, and testing of members and connections for electrical transmission structures. These...

Loading, Geometry, and Analysis
This Standard applies to latticed steel transmission structures. These structures shall be either self-supporting or guyed. They consist of hot-rolled or cold-formed prismatic members...

Design of Connections
Bolted connections for transmission structures are normally designed as bearing type connections. It is assumed that bolts connecting one member to another carry the load in the connection...

Testing
The purchaser shall specify in the contract documents which structures or components of structures are to be tested. If a proof test of a structure or a component of a structure is specified,...

Structural Members and Connections Used in Foundations
This chapter specifies design procedures for steel members and connections embedded in concrete foundations or the earth. Additional design requirements for structural members and connections...

Shafts/Temporary Structures
Shafts should be of a size to accommodate the equipment and pipe selected and to allow for safe working practices. If the shaft must accommodate the permanent works, it is the contractor's...

Construction Support Services
A preconstruction survey of existing structures within the anticipated construction zone of influence should be conducted before any construction begins. A plan for structures that need...

The New Bedford Marine Commerce Terminal
When construction of the first American offshore wind farm support terminal encountered greater challenges than expected, jet grouting enabled construction to continue....

Notes on Heavy Lift Design
The interrelated activities and responsibilities of the various organizations involved in the lift design and offshore installation of topside facilities for an offshore platform are discussed....

Performance Limits for Deepwater Pipelines
This paper highlights the differences between onshore and offshore pipeline design. It then summarizes the results of combined external pressure, tension, and bending testing on full scale...

Failure of a Twenty-Foot High Retaining Wall
A cantilever retaining wall, designed in apparent accord with provisions in a civil engineering handbook, failed soon after construction. Analyses of the causes of the failure are presented....

Offshore Technology in Civil Engineering
Hall of Fame Papers from the Early Years
Prepared by the Program Committee of the Offshore Technology Conference of the Coasts, Oceans, Ports, and Rivers Institute of ASCE. This series presents...

Advanced Fracture Control Procedures for Deepwater Platforms and Compliant Towers
This paper describes an integrated approach to fracture control problems � applied first as a necessary adjunct to the authors' own engineering practice, then in developing...

Case Study of Offshore Pile System Reliability
This paper presents the results of research effort to evaluate the reliability of offshore pile foundation systems. It is an extension of previous work by the authors [14] dealing with...

Offshore Platform Steel Specification
The discovery in the 1980's of local brittle zones (LBZ's) in and near the heat-affected zone (HAZ) of the fabrication welds in certain offshore platform steels...

Geo-Shanghai 2014
Proceedings of the Geo-Shanghai 2014 International Conference, held in Shanghai, China, May 26-28, 2014. Sponsored by the Geo-Institute of ASCE. These...

Asset Management of Earth Retaining Structures: Design through Design Life
Regarding new earth retaining structures (ERS) construction, the message is clear: plan for asset management. New construction is certainly not immune to performance issues, and the time...

Development and Use of Force Pulse Train Generators

Hybrid Modelling of Seismic Structure Interaction

A Fault-Rupture Propagation Model for Ground Motion Simulation

 

 

 

 