CADD?Database Application for Facility Inspections
In 1989, the Sverdrup Corporation was hired to perform the Comprehensive Inspection of the Queens-Midtown and Brooklyn-Battery tunnels in New York City. From the onset of the project it...

Subsurface Pavement Structure Inventory Using Ground Penetrating Radar and a Bore Hole Camera
The Pavement Management System (PMS) is now a necessary pavement evaluation tool. The PMS data base has been historically fed with surface inspection data, but increasing demands for accurate...

Probabilistic Risk Analysis of TLP Tether Fracture
A stochastic model for fatigue crack growth and final fracture of TLP tethers is formulated. Model updating through in-service inspection is included. The integrity of the cracked tether...

Adaptive Reliability-Based Inspection Strategies for Structures Subject to Fatigue
Metallic structures subject to substantial load-induced fatigue must be inspected from time to time and, possibly, repaired or even put out of service if the damage has reached critical...

Application of Fuzzy-Bayesian Analysis to Structural Reliability
The purpose of this study is to develop a fuzzy-Bayesian reliability approach for the decision of proper inspection schedule to maintain structural integrity. According to this approach,...

Optimal Inspection Planning for Fatigue Damage of Offshore Structures
A formulation of optimal design, inspection and maintenance against damage caused by fatigue crack growth is formulated. A stochastic model for fatigue crack growth based on linear elastic...

Optimal Strategies for Design, Inspection, and Repair of Fatigue-Sensitive Structural Systems Using Risk-Based Economics
The fatigue reliability and maintainability process for a marine structure (caisson platform) is studied. Reliability analysis, performed by Monte Carlo, quantifies the improvement in...

Strategies for Bridge Inspection Using Probabilistic Models
This paper describes the application of probability analyses in planning an inspection program for highway bridges. When damage in the form of fracture and cracking is the major concern,...

The Effect of Repeated Inspections on the Reliability Degradation Due to Fatigue Crack Growth
The effect of repeated in-service inspections on the reliability degradation due to fatigue crack growth is investigated based upon a stochastic fracture mechanics. A method to evaluate...

Bayesian Reliability Analysis of Structures with Multiple Components
This study develops a method of Bayesian reliability analysis to establish an optimal inspection schedule of structures with multiple components using the data collected during inservice...

Reliability Assessment of Pressurized Fuselages with Multiple-Site Fatigue Cracks
Multiple-site damage could cause a catastrophic structural failure of aged aircraft. A reliability analysis is proposed for an assessment of the capability of visual inspection on multiple-site...

Corrosion Protection of Cast Iron and Ductile Iron Pipe, San Diego, California
This paper addresses the use of a loose unbonded plastic covering polyethylene encasement for protection of cast and ductile iron pipe in an extremely corrosive soil. The case study in...

Restoration of a Buttress Dam
Inspections of Morris Shepard Dam on the Brazos River in Texas revealed serious defects in the dam and its foundation. Piezometric pressures below the spillway buttresses greatly exceeded...

Bridges Under Surveillance
Although bridge monitoring is still in its infancy, research, pilot studies and field work are underway across the country. While today it's still a pie-in-the-sky goal, the...

Recognition and Avoidance of Details That Adversely Affect the Performance of Exposed Wood Members
Factors that affect the deterioration of wood in structures are reviewed. Important points regarding wood-moisture relationships are noted. The requirements for decay of wood by fungi...

U.S. Coast Guard Experience with Commercial FRP Vessels with Respect to Structural Reliability
The U.S. Coast Guard currently inspects over 1000 fiber reinforced plastic (FRP) vessels used in commercial passenger service. The designs include monohulls, catamarans, hydrofoils and...

Postearthquake Safety Evaluation of Buildings
Procedures for the safety evaluation of buildings in earthquake damaged areas have been developed. Two evaluation techniques, Rapid Screening and Detailed Inspection, are described. Rapid...

Impact of Risk-Based Analysis on Hydrologic Design Practices
This paper provides a brief review of the current hydrologic design practices of the U.S. Army Corps of Engineers (USACOE) for safety inspection of dams and the current hydrologic design...

Underwater Tunnel Inspection by Virginia Power Using a Submersible Robot
The Bath County Pumped Storage Station, has three large tunnels linking the upper and lower reservoirs. The 'Hydrover' submersible remotely operated vehicle (ROV)...

Underwater Tunnel Inspection by Virginia Power Using a Submersible Robot
The Bath County Pumped Storage Station, jointly owned by Virginia Power and Allegheny Power systems and operated by Virginia Power, has three large tunnels linking the upper and lower...

 

 

 

 

Return to search